Idd Meter Adjustment - Yaesu FTDX3000 Technical Supplement

Hide thumbs Also See for FTDX3000:
Table of Contents

Advertisement

IDD Meter Adjustment

Choose one of the adjustment methods described
below, according to the equipment you have avail-
able. If you perform adjustment method (2) Using
a DC Ammeter, complete the transmit adjustments
on ALIGNMENT page 11 through 17.
1) Using an Electronic Load
 Remove the jumper that is connected between
J5008 and J5009 on the PA-Unit, then connect
the Electronic Load to J5008 and GND.
 Set the VFO-A frequency to 14.200 MHz in the
CW mode.
 Press and hold in the [1.8(1)], [3.5(2)], and [7(3)]
keys, while turning the radio on, to enter the
alignment mode.
 Rotate the Main Tuning Dial knob to select the
alignment parameter "24-01 IDD MTR".
 Press the PTT button, then adjust the Electronic
Load to "10 A".
 Press the [ENT] key, then release the PTT but-
ton.
 Press and hold in the [MENU] button for one
second to save the new setting and exit the
alignment mode.
PA U
A
nit
J5008
J5009
P
lignment
oints
ALIGNMENT-19
2) Using a DC Ammeter
 Connect the 50-Ohm Dummy Load and Watt-
meter to the "ANT 1" jack.
 Remove the jumper that is connected between
J5008 and J5009 on the PA-Unit, then connect
the DC ammeter (20-A range) between J5008
and J5009.
 Set the VFO-A frequency to 14.200 MHz in the
CW mode.
 Press and hold in the [1.8(1)], [3.5(2)], and [7(3)]
keys, while turning the radio on, to enter the
alignment mode.
 Rotate the Main Tuning Dial knob to select the
alignment parameter "24-01 IDD-MTR".
 Press the [MOX] button, then rotate the [PROC/
CAR] knob so that the DC ammeter reading is
"10 amperes".
 Press the [ENT] key, then release the [MOX]
button.
 Press and hold in the [MENU] button for one
second to save the new setting and exit the
alignment mode.