Yaesu FTDX3000 Technical Supplement page 18

Hide thumbs Also See for FTDX3000:
Table of Contents

Advertisement

MCF Adjustment (2)
 Set the VFO-A frequency to 14.200 MHz in the
CW-USB mode.
 Set the following controls as indicated:
[ANT] : ANT 1
[IPO] : AMP1
[ATT] : OFF
[µ-TUNE] : THRU
[R.FLT] : 15 kHz
[AGC] : AUTO
[RF GAIN] : Fully clockwise
 Connect the AF millivoltmeter and 4 Ohm
dummy load to the EXT SP jack.
 Connect the RF Signal Generator to the "ANT
1" jack, then set the output level to 0 dBµ at the
14.200 MHz.
 Adjust T1038 and T1034 on the MAIN Unit in
succession several times for maximum deflec-
tion on the AF millivoltmeter.
Note: If the S-meter deflects while adjusting, re-
duce the RF Signal Generator output so that the
S-meter does not deflect.
T1038
L1085
VR1003
( R
mAin U
nit
eCeiveR
ALIGNMENT-7
IF Trap Adjustment
 Set the VFO-A frequency to 10.100 MHz in the
CW-USB mode.
 Set the following controls as indicated:
[ANT] : ANT 1
[IPO] : AMP1
[ATT] : OFF
[R.FLT] : 3 kHz
[AGC] : AUTO
[RF GAIN] : Fully clockwise
 Connect the AF millivoltmeter and 4 Ohm
dummy load to the EXT SP jack.
 Connect the RF Signal Generator to the "ANT 1"
jack, then set the output level to +40 ~ +80 dBµ
at the 9.000 MHz.
 Adjust L1085 and VR1003 on the MAIN Unit
for minimum deflection on the AF millivoltme-
ter.
Note: If the S-meter deflects while adjusting, re-
duce the RF Signal Generator output so that the
S-meter does not deflect.
T1034