Table 1 - General Data
Boiler Size
Gas supply
Gas Supply Connection
Injector size
Flow Connection
Return Connection
Flue Terminal Diameter
Maximum Working Pressure (Sealed Systems)
Electrical Supply / Power consumption
Fuse Rating
Water content
Packaged Weight
Maximum Installation Weight
Boiler Casing Size
Table 2 - Performance Data
Boiler Size
Boiler input 'Q' =
Nett CV
Gross CV
Boiler output 'P' =
Gas consumption
70
temperature
40
temperature
Seasonal efficiency (SEDBUK) *
NOx classification
*
The value is used in the UK Government's Standard Assessment Procedure (SAP) for energy rating of dwellings. The test data from
which it has been calculated have been certified by a notified body.
Note. Gas consumption is calculated using a
calorific value of 38.7 MJ/m
gross or 34.9 MJ/m
(935 Btu/ft
3
To obtain the gas consumption at a different
calorific value:
a. For l/s - divide the gross heat input (kW) by
the gross C.V. of the gas (MJ/m
3
b. For ft
/h - divide the gross heat input (Btu/
h) by the gross C.V. of the gas (Btu/ft
CAUTION.
To avoid the possibility of injury during the installation, servicing or cleaning of
this appliance care should be taken when handling edges of sheet steel components.
4
Central Heating
Height
Width
Depth
kW
Btu/h
kW
Btu/h
l/s (cu.ft/h)
o
C Mean water
kW
Btu/h
o
C Mean water
kW
Btu/h
Band A
3
(1038 Btu/ft
3
)
) nett
3
)
3
)
3
GENERAL
Central Heating
Central Heating
mm (in)
bar (lb/in
)
2
litre (gal)
kg (lb)
kg (lb)
mm (in)
mm (in)
mm (in)
HE15 Max
15.1
51,500
16.8
57,200
0.43 (54.7)
14.6
50,000
15.5
53,000
[90.4]%
Key to symbols
GB = United Kingdom IE = Ireland (Countries of destination)
PMS = Maximum operating pressure of water
C
C
C
= A room sealed appliance designed for connection via ducts to a
13
33
53
horizontal or vertical terminal, which admits fresh air to the burner
and discharges the products of combustion to the outside through
orifices which, in this case, are concentric. The fan is up stream of
the combustion chamber.
I
= An appliance designed for use on 2nd Family gas, Group H only.
2H
HE15
2H-G20-20mbar
Rc1/2 (1/2" BSP Female)
Stereomatic 5.6mm dia.
22mm copper compression
22mm copper compression
100 (4)
2.5 (36.3)
230 V ~ 50 Hz. / 148 W
External : 3A Internal : T3.15A L 250V
2.0 (0.44)
50 (110)
40 (88)
687 (27)
390 (15 3/8)
278 (11)
HE24 Max
HE15, HE24 Min
24.4
83,300
27.1
92,500
0.70 (89.0)
23.4
80,000
25.1
85,700
[90.2]%
Class 5
icos system -
Installation and Servicing
HE24
9.1
31,000
10.1
34,400
0.26 (33.2)
8.8
30,000
9.6
32,800

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Icos system he24

Table of Contents