BOILER SEALING PANEL / BOTTOM PANEL REMOVAL
1. To remove the sealing panel remove the 4
screws.
2. Remove the panel.
3. To remove the bottom panel remove the 2
screws.
4. Pull the right hand side of the panel down.
Slide it to the right and withdraw.
49 THE CONTROL BOX IN THE SERVICING POSITION
1. Remove the 2 screws and withdraw the user
control.
2. Unplug the low voltage electrical lead from the
back of the user control.
3. Turn the clamp, swing the control box down and
pull slightly forward.