TECHNICAL SPECIFICATIONS

Host Connection
IBM® S/3x (System 34, 36, 38) host, AS/400™ host
or 5x94 remote controller
Dimensions
4.75" x 3.0" x 1.0"
Shipping Weight
2 pounds
Power Supply Requirements Replace power supply with only the equivalent
input rating (see below) and output rating (regulated 9VDC at 0.5 A).
PN
3525
3525
3518
3514
3525
Environment
Typical Operating Temperature*: 0°
Storage Temperature:
Humidity
Altitude
DECLARATION OF CONFORMITY
Name of Mfg:
Black Box Corporation
1000 Park Drive, Lawrence PA 15055 USA
Model:
IC263 Series Repeaters
Part Number(s):
IC263A
Regulation:
EMC Directive 89/336/EEC
Purpose: To declare that the IC263A to which this declaration refers is in
conformity with the following standards.
EMC-CISPR 22: 1985 Class A&B; EN 55022: 1988 Class A&B; EN 50082-1:1992;
EN 60950 A4:1997; IEC 801.2, IEC 801.3, and IEC 801.4; IEC 950
I, the undersigned, hereby declare that the equipment specified above conforms to the
above Directive(s) and Standard(s).
Stephen Anderson, Vice-President of Engineering
(119mm x 76mm x 25mm)
(0.9 kilograms)
Requirement
Location
240 volts, 50 hertz
United Kingdom
230 volts, 50 hertz
Europe
120 volts, 60 hertz
USA/Canada/Mexico
100 volts, 50-60 hertz Japan
240 volts, 50 hertz
Australia
50°C (32°
122°F )
to
to
-20°
85°C (-4°
185°F)
to
to
10-90%, non condensing
0-10,000 feet