Download Print this page

Cable Specifications - Black Box 5250 User Manual

Advertisement

CABLE SPECIFICATIONS

The physical characteristics of the cable must meet or exceed the following:
Fiber Cable
MULTIMODE
Fiber Optic Cable Recommended:
Fiber Optic Transmitter Power:
Fiber Optic Receiver Sensitivity:
Wavelength:
Bit error rate:
Maximum Cable Distance:
SINGLEMODE
Fiber Optic Cable Recommended:
Fiber Optic Transmitter Power:
Fiber Optic Receiver Sensitivity:
Wavelength:
Bit error rate:
Maximum Cable Distance:
Copper Cable
Category 3 wire or better is required; category 5 wire is recommended. Either
shielded twisted pair (STP) or unshielded twisted pair (UTP) can be used. DO
NOT USE FLAT OR SILVER SATIN WIRE.
Category 3:
Gauge
Attenuation
Differential Characteristic Impedance
Category 5:
Gauge
Attenuation
Differential Characteristic Impedance
Minimum UTP/STP Cable Distance:
Maximum UTP/STP Cable Distance:
Connector:
Straight Through Cable
3
3
4
4
RJ-45
RJ-45
connector
connector
5
5
6
6
62.5 / 125 µm multimode fiber
min: -19.0
max: -14.0
dBm
min: -32.5
max: -14.0
dBm
850nM
≤10
-9
2 kilometers
9 µm singlemode fiber
min: -27.0
max: -17.0
dBm
min: -32.5
max: -13.0
dBm
1300nM
≤10
-9
8 kilometers
24 to 22 AWG
28 dB/1000' @ 10 MHz
100 Ω ±10% @ 10 MHz
24 to 22 AWG
20 dB/1000' @ 10 MHz
100 Ω ±10% @ 10 MHz
7.6 meters (25 feet)
)
762 meters (2500 feet
RJ-45 connectors with active
pair pins 4 & 5.
NOTE: The active pair in a twisted-pair
copper 5250-compliant network are pins
4 & 5. Use only dedicated wire pairs (such
as blue/white & white/blue, orange/white
& white/orange) for the active pins.
INSTALLATION
All cable connections to the IC263A MUST be AT LEAST
7.6 meters (25 feet) in length.
Install Cable
Connect Host Signal to IC263A Repeater:
dBm
dBm
1.
NOTE: Install Black Box Corporation balun part number: 3-4554
between RJ-45 cable and Twinax connector.
dBm
2.
dBm
3.
4.
Connect IC263A Repeater Pair:
1.
2.
3.
4.
5.
Locate or build twisted-pair cables that are compliant with cable
specifications and with male RJ-45 plug connectors installed at
both cable ends.
Install balun at host Twinax connector.
Connect male RJ-45 plug connector at one end of twisted pair
cable to balun on host Twinax connector.
Connect male RJ-45 plug connector at other end of twisted pair
cable to female RJ-45 connector on IC263A repeater.
Locate or build fiber cable that conforms to cable specifications and
with male fiber connectors installed at both ends.
TX
RX
Connect one end of first fiber cable to IC263A repeater TX
connector.
Connect other end of that fiber cable to second IC263A repeater RX
connector.
Connect one end of second fiber cable to IC263A repeater RX
connector.
Connect other end of that fiber cable to second IC263A repeater TX
connector.
TX
RX

Advertisement