Advertisement

Quick Links

Twin Mux Repeater Module – UTP
Twin Mux Repeater Module – Fiber
CUSTOMER
SUPPORT
INFORMATION
1
0
R
P O W E
Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500)
FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746
Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018
Web site: www.blackbox.com • E-mail: info@blackbox.com
6
5
4
3
2
FEBRUARY 1996
M O D E
C T R L
P L IN K
B A C K -U
E R R
T E R M
P A R IT Y
IN K
M A IN L
E R R
O L
P A R IT Y
S Y N C /P
7
O L
S Y N C /P
IC092C
IC093C

Advertisement

Table of Contents
loading

Summary of Contents for Black Box Twin Mux Repeater Module – UTP

  • Page 1 Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 SUPPORT Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018 INFORMATION Web site: www.blackbox.com • E-mail: info@blackbox.com...
  • Page 2 TWIN MUX REPEATER MODULES FEDERAL COMMUNICATIONS COMMISSION CANADIAN DEPARTMENT OF COMMUNICATIONS RADIO FREQUENCY INTERFERENCE STATEMENTS This equipment generates, uses, and can radiate radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection against...
  • Page 3 TWIN MUX REPEATER MODULES NORMAS OFICIALES MEXICANAS (NOM) ELECTRICAL SAFETY STATEMENT INSTRUCCIONES DE SEGURIDAD 1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado. 2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura.
  • Page 4 TWIN MUX REPEATER MODULES 12. Precaución debe ser tomada de tal manera que la tierra fisica y la polarización del equipo no sea eliminada. 13. Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados sobre o contra ellos, poniendo particular atención a los contactos y receptáculos donde salen del aparato.
  • Page 5: Table Of Contents

    TWIN MUX REPEATER MODULES Contents Chapter Page 1. Specifications ..................7 2. Introduction..................9 3. Installation ....................12 3.1 Basic Installation ................12 3.1.1 Pin Configuration ...............14 3.1.2 Polarity Switch..............14 3.1.3 Ctrl/Term Mode Switch.............14 3.1.4 Location Selection ..............14 3.1.5 Installing the Twin Mux Repeater Module in the Power Cage................16 3.1.6 Wiring and Polarity Switch Setting ........17 3.1.7 Verifying ................18...
  • Page 6: Specifications

    TWIN MUX REPEATER MODULES 1. Specifications Environment—IBM System 34/36/38 and AS/400 Devices—IBM System 3X-AS/400 controllers and compatible peripherals (such as system terminals and printers, etc.) Data Rate—Signal Frequency: 1 MHz ± 3.69% Cable—Fiber: Dual Fiber, Multimode graded index: Core/clad: 62.5/125 µm Numerical aperture: 0.275 Attenuation: 4.5 dB/km (850 nm) Minimum bandwidth: 160 MHz-km (850 nm)
  • Page 7 TWIN MUX REPEATER MODULES Distances—Ctrl distance: 2000 feet (610 m), Term distance (daisy-chain): 700 feet (213 m) to 2000 feet (610 m), Term distance (star-config.): 2000 feet (610 m), Link distance: 2500 feet (762 m); 8200 feet (2500 m) (with Fiber)Distances are calculated using Category 3 cable as specified above.
  • Page 8: Introduction

    TWIN MUX REPEATER MODULES 2. Introduction The Twin Mux Repeater Module is a hot-swappable 8-port multiplexor for the Power Cage 500 Solution (RM601A) for use in the IBM S/3X or AS/400 ® ® environment. The Twin Mux Repeater Module lets you combine eight host ports over one fiber, UTP, or STP cable pair for more cost-effective cabling installations.
  • Page 9 TWIN MUX REPEATER MODULES Features • Hot-swappable 8-port multiplexor. • Same unit can be used on controller or workstation side (switch-selectable). • Doubles the distance between each workstation and the controller. • True repeater technology; bi-directional. • Data amplitude, timing and duty cycle corrected to remove jitter. •...
  • Page 10 TWIN MUX REPEATER MODULES • Diagnostic Parity Error LED on each controller (Ctrl), workstation (Term) and link ports. • Intelligent Line Sync/Polarity LEDs will light only for a true IBM System 3X or AS/400 signal received in the correct polarity. •...
  • Page 11: Installation

    TWIN MUX REPEATER MODULES 3. Installation 3.1 Basic Installation Follow the steps below to properly install the Twin Mux Repeater Module. NOTE The RJ-45 connectors of the Twin Mux Repeater Module are designed for use with (part number IC065) 3X or AS/400 baluns. If you use other balun, you might have to reverse the polarity of the Twin Mux Repeater Module via the polarity DIP switch.
  • Page 12 TWIN MUX REPEATER MODULES NHC STD OPTIONAL PIN CONFIGURATION JUMPERS RJ45 P4&5 RJ45 P1&2 AND DIP SWITCH TWINMUX MODULE-TOP VIEW POLARITY SWITCH POLARITY REVERSED CTRL/TERM MODE CTRL TERM MODE MODE Figure 3-2. Pin Configuration Jumpers and DIP Switch.
  • Page 13: Pin Configuration

    TWIN MUX REPEATER MODULES 3.1.1 P ONFIGURATION You can change the pin configuration via the jumper switches on the printed circuit board. The pin configuration of each RJ-45 connector is factory-set to RJ-45 pins 4 and 5. In order to set the pin configuration to pins 1 and 2, move the jumper located beside each RJ-45 connector to the “1 and 2”...
  • Page 14 TWIN MUX REPEATER MODULES RJ-45 Link Versions Only Select a location for the Ctrl Twin Mux Repeater Module within 2500 feet (762 m) of the Term Twin Mux Repeater Module. These distances assume that the cable used conforms to the cable specifications given in Chapter 1. Ctrl Twin Mux Repeater Module Select a location for the Ctrl Twin Mux Repeater Module within 2000 feet (610 m) of the controller.
  • Page 15: Installing The Twin Mux Repeater Module In The Power Cage

    TWIN MUX REPEATER MODULES Term Twin Mux Repeater Module with Star Configuration Select a location for the Term Twin Mux Repeater Module within 2000 feet (610 m) of the Multiple Twinax Repeater III. The workstations can be up to 2500 feet (762 m) away from the Repeater III in a star configuration. NOTE Remember to terminate all the terminals and printers after the Multiple Twinax Repeater III.
  • Page 16: Wiring And Polarity Switch Setting

    TWIN MUX REPEATER MODULES M O DE CT RL TE RM -U P LI TY ER BA CK PA RI IN K /P O L M AI NL TY ER SY NC PA RI /P OL SY NC M O DE CT RL TE RM -U P LI...
  • Page 17: Verifying

    TWIN MUX REPEATER MODULES Avoid using 50- and 100-pair cable when trying to achieve optimum performance, since it may add to cross-talk and capacitance problems. Never use flat cable (cable that is not twisted, sometimes referred to as silver satin), not even for patching short runs. Flat cable will act as an antenna and pick up nearby radio-frequency or electromagnetic radiation interference that cannot be removed.
  • Page 18: Link Connections

    TWIN MUX REPEATER MODULES 3.1.9 L ONNECTIONS Connect the Main and Backup Links of the Ctrl Twin Mux Repeater Module to the Term Twin Mux Repeater Module. Begin by connecting the Main Link first. If the controller end of the cable is also connected, then the corresponding green Main Link “Line Sync/Polarity”...
  • Page 19: Workstation Connections

    TWIN MUX REPEATER MODULES NOTE When both the Main and Backup Links are functioning properly, only the Main Link “Line Sync/Polarity” LED should be ON because it has priority. If the Main Link for some reason is inactive, then the Backup Link “Line Sync/Polarity”...
  • Page 20: Typical Installations

    TWIN MUX REPEATER MODULES 3.2 Typical Installations 2000' UTP/STP Main Link Back-Up Link Back-Up Link 2500' UTP/STP TWINMUX AS/400 8200' Fiber (Ctrl Mode) 700 to 2000' UTP/STP ** Port 0 TWINMUX 700 to 2000' UTP/STP Port 7 (Term Mode) Remember to always terminate the last workstation on a port.
  • Page 21 TWIN MUX REPEATER MODULES Main Link Back-Up Link Back-Up Link 2500' UTP/STP Addr 0 TWINMUX AS/400 8200' Fiber (Ctrl Mode) Port 0 2000' UTP/STP IC106C Addr 6 TWINMUX (Term Mode) 2500' UTP/STP Addr 0 Port 7 2000' UTP/STP IC106C Addr 6 2500' UTP/STP * Baluns are used at each terminal and each controller port.
  • Page 22 TWIN MUX REPEATER MODULES Twinax Device BUILDING B Punch Block UTP or Fiber Patch Patch (1 pair) Panels Cords Balun Star Hubs BUILDING A Port 1 MAINLINK BACK-UP LINK MODE MAINLINK BACK-UP LINK MODE POWER PARITY ERR PARITY ERR CTRL POWER PARITY ERR PARITY ERR...
  • Page 23: Troubleshooting

    TWIN MUX REPEATER MODULES 4. Troubleshooting If any step in Chapter 3 fails, please follow the procedures below before calling for assistance. If you still have trouble after following these suggestions, read the Technical Support Information at the end of this chapter before calling for technical support.
  • Page 24 TWIN MUX REPEATER MODULES • Problem: The Power LED does not light. • Solution: 1. Verify that the power cord is properly connected to the Power Cage. 2. Verify that the wallplate is live by plugging in some other powered device. •...
  • Page 25 TWIN MUX REPEATER MODULES 6. Verify that the balun pin-outs match that of the Twin Mux Repeater Module. Both the Twin Mux Repeater Module and the IC065 baluns should have an ohm-meter reading of less than 1 ohm across their active pins.
  • Page 26 TWIN MUX REPEATER MODULES NOTE Different terminals terminate in different ways. Some have termination switches, while others terminate via a self-terminating Twinax “T” or “Y” splitter cable. Improper termination settings can cause intermittent problems. 2. Verify that the pair of wires used are in fact twisted with each other and not with other wires (i.e., check for split pairs).
  • Page 27 TWIN MUX REPEATER MODULES Technical Support Information When contacting Technical Support, please have the following information ready: 1. Unit type (fiber or copper version with pin-out information). 2. Balun type used. 3. Unit serial number. 4. Environment lay-out. Include controller and workstations used (with model numbers), estimated cable lengths (between what equipment) and type of cable used (UTP, STP, Flat, 25-pair, 50-pair or 100-pair).
  • Page 28 © Copyright 1996. Black Box Corporation. All rights reserved. 1000 Park Drive • Lawrence, PA 15055-1018 • 724-746-5500 • Fax 724-746-0746...

This manual is also suitable for:

Twin mux repeater module – fiber

Table of Contents