C. Constructing the Appliance Chase
A chase is a vertical box-like structure built to enclose the
gas appliance and/or its vent system. In cooler climates
the vent should be enclosed inside the chase.
NOTICE: Treatment of ceiling firestops and wall shield
firestops and construction of the chase may vary with the
type of building. These instructions are not substitutes
for the requirements of local building codes. Therefore,
you MUST check local building codes to determine the
requirements to these steps.
To further prevent drafts, the wall shield and ceiling fire-
stops should be caulked with caulk with a minimum of
300ºF continuous exposure rating to seal gaps. Gas
line holes and other openings should be caulked with
caulk with a minimum of 300ºF continuous exposure rating
or stuffed with unfaced insulation. If the appliance is being
installed on a cement surface, a layer of plywood may be
placed underneath to prevent conducting cold up into the
room.
Heatilator • ION-V7, ION-S7, ION-H7 Installation Manual • 2276-980 Rev. E • 5/15
D. Floor Protection
WARNING! Risk of overheating! Install appliance a
minimum of 4 inches off of finished floor.
• Convection air flow could be compromised and cause
overheating.
• Decorative fronts will not fit properly.
• The finished floor below the appliance does not have to
be non-combustible, due to the required 4 inch minimum
clearance from bottom of appliance to finished floor.