PANEL CONTROLS (SEE FIGURE 22)
The blowers and automatic fuel supply are controlled from a panel on the left-hand
side of the 5040. The control panel functions are as follows.
a. ON/OFF SWITCH
When pushed the stove will automatically ignite. No other fi restarter is necessary.
The igniter will stay on for at least 10 and up to 15 minutes, depending on when
Proof of Fire is reached. The fi re should start in about 5 minutes.
The green light located above the On/Off button (in the On/Off box) will fl ash dur-
ing the ignition start-up period. (See fi gure 22)
The Feed Rate Advance is inoperable during the ignition start period. When
the red light continuously stays on the Feed Rate Advance can be adjusted to
achieve the desired heat output.
NOTE: If the stove has been shut off, and you want to re-start it while it is still warm,
the "on/off" button must be held down for 2 seconds.
b. FUEL FEED SWITCH
When the "Fuel Feed" button is pushed and held down the stove will feed pellets
continuously into the burnpot.
While the stove's auger system is feeding pellets the amber light (in the "Fuel
Feed" box) will be on. (See fi gure 22)
CAUTION: DO NOT USE THIS CONTROL DURING NORMAL OPERATION BE-
CAUSE IT COULD SMOTHER THE FIRE AND LEAD TO A DANGEROUS SITUA-
TION.
c. HIGH FAN SWITCH
The room air fan speed varies directly with the feed rate. The "HIGH FAN" switch
overrides this variable speed function. It will set the room air blower speed to high
at any feed rate setting.
When the "HIGH FAN" button is pushed the room air fan will switch to its highest
setting.
When this button is pushed again the room air fan will return to its original setting based on the Feed Rate Advance
setting.
d. RESET TRIM
Different size and quality pellet fuel may require adjustment of the "1" feed setting on the Feed Rate Advance bar graph.
This is usually a one-time adjustment based on the fuel you are using. The "RESET TRIM" button when adjusted will allow
for 3 different feed rate settings for the #1 feed setting only. To adjust simply push the "RESET TRIM" button while the stove
is operating at setting "1" and watch the bar graph.
When the "1" and "3" lights are illuminated on the bar graph the low feed rate is at its
pounds per hour)
When the "1" light is illuminated on the bar graph the low feed rate is at its "normal" setting.
When the "1" & "4" lights are illuminated on the bar graph the low feed rate is at its "highest" setting.
NOTE: When the stove is set on "1" the "reset trim" values will be shown on the Feed Rate Advance bar graph. For example
if the Reset Trim is set to its lowest setting every time the stove is set to low the "1" and "3" lights will be illuminated on the
bar graph.
e. HEAT LEVEL ADVANCE
This button when pushed will set the pellet feed rate, hence the heat output of your stove. The levels of heat output will
incrementally change on the bar graph starting from level "1" to "4".
NOTE: When dropping more than 2 heat level settings (i.e. 4 to 1) push the 'High Fan' button and allow the room air fan to
run at that setting for at least 5 minutes to prevent the stove from tripping the high temp thermodisc. If the high temp ther-
modisc does trip see "SAFETY FEATURES".
CAUTION: THE "4" SETTING IS DESIGNED FOR TEMPORARY USE ONLY. IF USED FOR EXTENDED PERIODS, IT
CAN SHORTEN THE LIFE EXPECTANCY OF THE UNITS COMPONENTS. AVOID USE AT THIS SETTING FOR MORE
THAN ONE HOUR AT A TIME.
12

OPERATION

OPERATION
"lowest" setting. (approx. 0.9