SPECIFICATIONS

FREESTANDING:
Width: 21 ½"
Height: 28 ½" (with legs or pedestal)
Depth: 24"
Weight: 185 lbs.
Pedestal: 40 lbs.
Legs: 13 lbs.
Flue size: 3" or 4"
Hopper Capacity: Up to 45 lbs.
(this can vary widely depending on pellet size, length, and diameter)
EPA status: exempt
Burn time: 1 lb. to 4 ½ lbs. per hour
BTU range: 8,200 to 40,000
Approved installations: mobile home, alcove, conventional
PREPARATION
Factory packaging must be removed, and some minor assembly work is re-
quired prior to installation. Access to the rear of the stove is necessary.
The circuit board/control panel must be unpacked and installed in the side fl ash-
ing on the insert or side panel on the freestanding. (See installation instructions
provided with the circuit board)
NOTE: Normally, your dealer will perform these functions.
CLEARANCES
The US Stove 5040 Freestanding has been tested and listed for installation in
residential, mobile home and alcove applications.
FLOOR PROTECTION: Freestanding installations, minimum 21" wide by 28"
deep. The stove must be placed on a continuous (grouted joints) noncombus-
tible material such as ceramic tile, cement board, brick, 3/8" millboard or equiva-
lent, or other approved or listed material suited for fl oor protection.
THE MATERIAL(S) USED MUST HAVE, OR COMBINE TO HAVE, A MINIMUM
INSULATIVE RATING OF 'R1'.
NOTE: ceramic tile, or any tile, requires a continuous sheet beneath to prevent
the possibility of embers falling through to the combustible fl oor if cracks or sep-
aration should occur in the fi nished surface, this would include fl oor protection
for Built-in raised hearths. Check local codes for approved alternatives.
Clearances are measured from the sides, back and face (door opening) or stove
body (refer to fi g. 4).
DO NOT USE MAKESHIFT MATERIALS OR COMPROMISES IN THE IN-
STALLATION OF THIS UNIT.
INSTALL VENT WITH CLEARANCES SPECIFIED BY THE VENT MANUFAC-
TURER.
CAUTION: DO NOT CONNECT TO OR USE IN CONJUNCTION WITH ANY
AIR DISTRIBUTION DUCTWORK UNLESS SPECIFICALLY APPROVED FOR
SUCH INSTALLATIONS.
6

INSTALLATION

INSTALLATION
SIDEWALL CLEARANCES
BACKWALL
ADJACENT WALL
WITH
3"
VERTICAL
*
1"
EXHAUST
8 1/4"
(TOP)
9"
(SIDEWALL)
FIGURE 1
36" MAX.
*
WITH HORIZONTAL EXHAUST
WITH
VERTICAL
48" MIN.
EXHAUST
8 1/4"
(TOP)
9"
(SIDEWALL)
STOVE DOOR FACE MUST BE
EQUAL TO OR PROTRUDE OUT
FROM FACE OF ALCOVE.
ALCOVE CLEARANCES
FIGURE 2
FIGURE 3
21"
6"
FLOOR PROTECTION
1"
3"
3"
1"
38" MIN.
BACKWALL
3"
1"
*
8 1/4"
(TOP)
9"
(SIDEWALL)
28"