E. VERTICALLY INTO EXISTING MASONRY
FIREPLACE
NOTE: Follow PL-Vent chimney manufacturer's
instructions.
1. 1. Have the masonry chimney inspected by a quali-
fi ed chimney sweep or installer to determine its struc-
tural condition.
2. 2. You will need a pipe length equal to the chimney
height from the hearth. If outside combustion air is
to be used,You will need a pipe length equal to the
chimney height plus 18 inches.
3. 3. Install a blanking plate and the chimney pipe, and
if used the outside air pipe, as shown in Figure 12.
4. Attach the PL-Vent adapter, a section of pipe and
clean out tee, making sure the clean out tee is cen-
tered in the chimney fl ue area. Use RTV, metallic
tape, and a minImum of three self-taping screws at
all joint connections to ensure a tight seal.
5. 5. Position the stove, adhering to the clearances in
Figures 1 & 2.
6. 6. Measure and build chimney top plate. Cut out
holes for chimney pipe, and if used the outside air
pipe. Install and seal with non-hardening mastic to
prevent water leakage. Install vent cap.
F.
INSTALLATION THROUGH SIDE OF MASONRY
CHIMNEY
NOTE: Follow PL-Vent chimney manufacturer's
instructions.
1. Position the stove, adhering to the clearances in
Figures 1 & 2. Mark the center of the hole where the
pipe is to pierce the masonry chimney.
2. It will be necessary to break out the masonry around
the location of the pipe center mark. Use a 4-inch
diameter hole for 3-inch pipe and 5-inch diameter
hole for 4-inch pipe.
3. Measure and build chimney top plate. Cut out holes
for chimney pipe, and if used the outside air pipe.
4. Install the tee on the bottom of the vertical pipe sys-
tem and lower it down the chimney until the center
branch of the tee is level with the center of the hole
in the masonry, as shown in Figure 13.
5. Install and seal the top plate from step 3 with non-
hardening mastic. Slip the storm collar over the pipe,
and while holding the pipe at the proper elevation, af-
fi x the collar with a minimum of three ¼" stainless steel
sheet metal screws. Seal all joints and seams around
the collar.
6. Connect the horizontal pipe by pushing it through the hole in the masonry and lining it up with the branch in the tee. Push
the pipe into the tee while twisting it to lock it into the tee.
7. If desired, once the horizontal pipe is in place, the space between the pipe and masonry may be fi lled with high-
temperature grout.
8. Install the trim collar. An adjustable pipe length and adapter may be needed to fi nish the connection to the stove.
10
INSTALLATION
INSTALLATION
6"
FROM STOVE
TO END OF HEARTH
6"
3"
NOTE:
FOLLOW METAL
CHIMNEY INSTALLATION
INSTRUCTIONS
TO
APPLIANCE
HEARTH
FIGURE 12
6"
3"
NOTE:
FOLLOW METAL
CHIMNEY INSTALLATION
INSTRUCTIONS
OPTIONAL OUTSIDE AIR
TRIM COLLAR
TO
APPLIANCE
FIGURE 13
TOP PLATE
(SEAL TO CHIMNEY TOP
WITH NON-HARDENING
MASTIC)
EXTENSION TO CHIMNEY TOP
REQUIRED.
3 OR 4 INCH STAINLESS STEEL
SINGLE WALL PIPE OR FLEX PIPE.
BLANKING PLATE (SEAL WITH
NON-HARDENING MASTIC).
3 OR 4 INCH STAINLESS STEEL
FLEX PIPE.
OPTIONAL OUTSIDE AIR
CLEAN-OUT-TEE (TYPE L)
OR 90 DEGREE ELBOW
TOP PLATE
(SEAL TO CHIMNEY TOP
WITH NON-HARDENING
MASTIC)
EXTENSION TO CHIMNEY TOP
REQUIRED.
L-VENT OR OPTIONAL
3 OR 4 INCH STAINLESS STEEL
SINGLE WALL PIPE OR FLEX PIPE.
PIPE ADAPTER
CLEAN-OUT TEE (TYPE L)