Vertically Into Existing Chimney System; Installation Through Side Of Masonry Chimney; Vertically Into Existing Masonry Fireplace - Golden Eagle 5040 Owner’s Instruction And Operation Manual

Hide thumbs Also See for 5040:
Table of Contents

Advertisement

under roofing materials, nail to the roof along upper
edge. Do not nail lower edge. Seal nail heads with
non-hardening waterproof mastic.
3. Apply non-hardening, waterproof mastic where the
storm collar will meet the vent and flashing. Slide
storm collar down until it sits on the flashing. Seal
and install cap. Mobile home installations must use
a spark arrester.
VERTICALLY INTO EXISTING CHIMNEY
SYSTEM
Adapters are available to adapt from 3" PL-Vent to 6" or
8" Class-A chimney. As an alternative, 3" or 4" PL-Vent
can be run inside existing chimney to termination. This
is the preferred method. Follow guidelines for equivalent
vent length.
EXISTING
CHIMNEY
SYSTEM
PELLET VENT TO
UNIVERSAL
CHIMNEY ADAPTER
CONNECTOR
VERTICALLY INTO EXISTING MASONRY
FIREPLACE
6" (153 mm)
3" (77 mm)
NOTE:
FOLLOW METAL
CHIMNEY
INSTALLATION
INSTRUCTIONS
6" (153 mm)
FROM STOVE
TO END OF
HEARTH
TO
APPLIANCE
HEARTH
1.
Have the masonry chimney inspected by a qualified
chimney sweep or installer to determine its structural
condition.
© 2021 United States Stove Company
EXISTING
CHIMNEY
SYSTEM
PELLET
NOTE:
VENT
THIS METHOD
IS PREFERRED
TOP PLATE
(SEAL TO CHIMNEY TOP
WITH NON-HARDENING
MASTIC)
EXTENSION TO CHIMNEY TOP
REQUIRED.
3 OR 4 INCH STAINLESS STEEL
SINGLE WALL PIPE OR FLEX PIPE.
BLANKING PLATE (SEAL WITH
NON-HARDENING MASTIC).
3 OR 4 INCH STAINLESS STEEL
FLEX PIPE.
OPTIONAL OUTSIDE AIR
CLEAN-OUT-TEE
OR 90 DEGREE ELBOW
2. You will need a pipe length equal to the chimney
height from the hearth. If outside combustion air is
to be used,You will need a pipe length equal to the
chimney height plus 18 inches.
3. Install a blanking plate and the chimney pipe, and if
used the outside air pipe, as shown.
4. Attach the PL-Vent adapter, a section of pipe and
clean out tee, making sure the clean out tee is
centered in the chimney flue area. Use RTV, metallic
tape, and a minimum of three self-taping screws at
all joint connections to ensure a tight seal.
5. Position the stove, adhering to the clearances.
6. Measure and build chimney top plate. Cut out holes
for chimney pipe, and if used the outside air pipe.
Install and seal with non-hardening mastic to prevent
water leakage. Install vent cap.
INSTALLATION THROUGH SIDE OF
MASONRY CHIMNEY
6" (153 mm)
3" (77 mm)
NOTE:
FOLLOW METAL
CHIMNEY
INSTALLATION
INSTRUCTIONS
OPTIONAL
OUTSIDE AIR
TRIM COLLAR
TO
APPLIANCE
1.
Position the stove, adhering to the clearances. Mark
the center of the hole where the pipe is to pierce the
masonry chimney.
2. It will be necessary to break out the masonry around
the location of the pipe center mark. Use a 4-inch
diameter hole for 3-inch pipe and 5-inch diameter
hole for 4-inch pipe.
3. Measure and build chimney top plate. Cut out holes
for chimney pipe, and if used the outside air pipe.
4. Install the tee on the bottom of the vertical pipe
system and lower it down the chimney until the
center branch of the tee is level with the center of the
hole in the masonry, as shown.
5. Install and seal the top plate from step 3 with non-
hardening mastic. Slip the storm collar over the pipe,
8
INSTALLATION
TOP PLATE
(SEAL TO CHIMNEY TOP
WITH NON-HARDENING
MASTIC)
EXTENSION TO CHIMNEY TOP
REQUIRED.
PL-VENT OR OPTIONAL
3 OR 4 INCH STAINLESS STEEL
SINGLE WALL PIPE OR FLEX PIPE.
PIPE ADAPTER
CLEAN-OUT TEE

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents