LAVAZZA LB GUZZINI Maintenance Manual For Technical Assistance page 16

Table of Contents

Advertisement

Maintenance manual for technical assistance - LB GUZZINI
- Unscrew the two screws and remove the ring (45).
- Unscrew the four screws (46).
46
46
- Lift up and remove the boiler ring (47).
Manual code 10083088 / Rel. 0.00 / January 2008
45
46
46
47
- Separate the upper boiler from the lower boiler.
It is possible to replace the gaskets (48) and (49).
48
- Press on the boiler piston to extract it.
- It is possible to replace the two gaskets (50) and(51).
50
49
51