ITEMS
Cooling capacity
Heat pump
Heating capacity
Moisture removal
Electrical data
Phase
Rated frequency
Rated voltage range
Rated voltage
Rated current
Rated input
Power factor
Compressor
Refrigerant system Evaporator
Noise level
(at cooling)
Fan system
Drive
Air flow quantity
Fan
Connections
Refrigerant coupling
Refrigerant tube size Gas, Liquid
Drain piping
Others
Safety device
Air filters
Net dimensions
Net weight
Note: The condition of star(

SPECIFICATIONS

INDOOR UNIT
AY-A07BE
kW
2.1
kW
2.4
Liters/h
0.7
Single
Hz
50
V
198 to 264
V
220 - 240
Cool
A
3.1 - 3.0
Heat
A
2.9 - 2.8
Cool
W
650 - 690
Heat
W
600 - 640
Cool
%
95 - 96
Heat
%
94 - 95
Type
Hermetically sealed rotary type
Model
QK134PA13A
Oil charge
300cc (SUNISO 4GSI)
Louver fin and Bare tube type
Condenser
Corrugate fin and Grooved tube type
Control
Capillary tube
Refrigerant volume
700g
De-Ice system
Micro computercontroled reverse systyem
High
dB(A)
33
Med.
dB(A)
29
Low
dB(A)
27
Direct drive
3
High
m
/min.
7.2
Med.
m
3
/min.
6.0
Low
m
3
/min.
4.8
Cross flow fan
Flare type
3/8", 1/4"
mm
O.D ø 18
Compressor: Overload protector
Fan motor: Thermal fuse
Fuse, Micro computer control
Polypropylene net (Washable)
Width
mm
815
Height
mm
278
Depth
mm
198
kg
9
) marked item are 'ISO5151' : 1994(E), condition T1.
OUTDOOR UNIT
INDOOR UNIT
AE-A07BE
AY-A07BE-C
RH135VHST
300cc (DIAMOND MS56)
650g
43
33
29
27
21
7.2
6.0
4.8
Propeller fan
Cross flow fan
Compressor: Overload protector
720
815
535
278
236
198
30
9
2
OUTDOOR UNIT
AE-A07BE-C
43
21
Propeller fan
(Internal)
720
535
236
30