Monaco Monarch 2000 Service Manual page 35

Table of Contents

Advertisement

Appliances & Equipment
Appliances & Equipment
AUTO Mode - 900 Series
Press main power ON/OFF button so that display light is lit.
• Press TEMP SET button and hold until coldest reading is indicated.
• Press and hold MODE button to select AUTO setting then release button.
Operating control automatically selects one of the following:
1. When 120 volt AC is available, "AUTO AC" will be visible in display panel indi-
cating refrigerator is operating on AC Current.
2. If 120 volt AC is not available, refrigerator will switch to LP gas operation and
"AUTO LP GAS" will be visible in display panel. If gas burner does not ignite
within 30 seconds refrigerator gas valve will automatically close, controls will
revert to a standby mode in which an alarm will sound and flashing LED dis-
play will indicate "A1". Turn refrigerator OFF to silence alarm. If gas burner
does not light after several tries, consult your authorized dealer for assistance.
If AC electric becomes available while refrigerator is operating in "AUTO LP
GAS" mode, refrigerator will switch to "AUTO AC" operation.
6 After the refrigerator is operating press "TEMP SET" button and adjust to desired
temperature.
Shut Down - 900 Series
Press ON/OFF button and hold until no indicator lights are lit. If the refrigerator
will not be in operation for a period of weeks it should be emptied, defrosted, cleaned and
the doors left ajar. Ice trays should be dried and kept outside the refrigerator.
Diagnostic Codes - 900 Series
Operating controls are equipped with a diagnostic systems which alerts to a prob-
lem in any mode of operation. When a problem occurs within a given mode, operating
controls will revert to a standby mode in which an alarm will sound and a diagnostic code
will flash in LED window. Turn the refrigerator OFF to silence the alarm and refer to
refrigerator Operator's manual for diagnostic meaning.
Operating Instructions - 1200 Series
A 12 volt DC supply is required to operate the refrigerator; if indicator lights are
not lit on the control panel when the refrigerator is turned on, check for loss of DC sup-
ply voltage. The shore line must be plugged in for 120 volt AC operation. The refrigera-
Monarch
M
ONACO
2000
3-3