Checking Your Wiring - Motorola MotoWI4 PTP 600 Series User Manual

Point-to-point wireless solutions
Hide thumbs Also See for MotoWI4 PTP 600 Series:
Table of Contents

Advertisement

Power Indoor Unit LED check chart:
Mode
No Power Applied
Power Applied
Valid Ethernet Link
and no traffic
Valid Ethernet Link
with traffic
Recovery
Switch
Pressed and held
for
>10
seconds
from
power
(Recovery
pressed
power is applied)

10.1.3 Checking your wiring

If the above procedures fail to diagnose the issue you may have a wiring fault. Unplug the
RJ45 from the PIDU+ and check the following resistances at the RJ45:
1. Check the cable resistance between pins 1 & 2, 3 & 6, 4 & 5 and 7 & 8 at the RJ45.
Check against column 2 in Table 14.
2. Check the cable resistance between pins 1 & 3 at the RJ45. Check against column 3 in
Table 14.
3. Check the cable resistance between pins 4 & 7 at the RJ45. Check against column 4 in
Table 14.
4. Ensure that there is greater than 100K ohms between pins 1 & 8 for all cable lengths.
Green LED
Off
On
On
On
on
On
is
while
Yellow LED No Ethernet
Cable Connected
Off
Will flash once per second
regularly approximately 30
seconds
after
power
applied for 10 seconds then
will go out and stay out
N/A
N/A
Off while switch pressed.
Approximately 30 seconds after releasing the
switch, flashes twice per second regularly for 10
seconds, then boots in "Recovery Mode"
While in "Recovery Mode" the unit will only be
accessible via the IP address 10.10.10.10.
155
Yellow
LED
Ethernet
Cable
Connected
between
PIDU
Plus
and
NIC/Switch/Hub
Off
Will flash once per
second
regularly
approximately
30
seconds after power
applied
for
10
seconds then operate
as
Ethernet
Link/Activity LED
Will be on solid for a
valid link.
Will be on solid, but
will blink randomly as
traffic passes through

Advertisement

Table of Contents
loading