Terminals; Accessories; Function Function Function Description Description; General Functions - Mastech my68 Instruction Manual

Handheld digital multimeter
Hide thumbs Also See for my68:
Table of Contents

Advertisement

2.5

2.5 Terminals

2.5
2.5
Terminals
Terminals
Terminals
See Table 4 indicated for information about the terminals.
Table
Table
Table 4. 4. 4. 4. Terminals
Terminals
Terminals
Table
Terminals
Terminal
Terminal
Terminal
Terminal
Return
terminal
( Receiving the black test lead or the "com"
COM
COM
COM
COM
plug of the optional clamp)
Input for voltage, resistance, frequency,
V V V V Ω Ω Ω Ω FCx
FCx
FCx
FCx
Capacitance, diode and continuity
measurements. (Receiving the red test lead)
Input
for
0.1 µ A
measurements. (Receiving the red test lead or
mA
mA
mA
mA
the "+" plug of the optional clamp)
Input for 400mA to 10A current measurements.
A A A A
(Receiving the red test lead)
2.6
2.6

Accessories

Accessories
2.6
2.6 Accessories
Accessories
Delivered with the multimeter:
¥ User's manual
¥ Carry case
¥ Test leads
¥ Holster
Optional:
¥ Clamp
11
Description
Description
Description
Description
for
all
measurements.
to
400mA
current
3. 3. 3. 3. FUNCTION
FUNCTION
FUNCTION
DESCRIPTION
DESCRIPTION
FUNCTION DESCRIPTION
DESCRIPTION
3.1
3.1 General
3.1
3.1
General

General Functions

General
Functions
Functions
Functions
3.1.1
3.1.1
DATA
DATA
HOLD
HOLD
mode
mode
3.1.1 DATA
3.1.1
DATA HOLD
HOLD mode
mode
Data Hold mode makes the meter stop updating the display.
Enabling Data Hold function in autorange mode makes the
meter switch to Manual ranging mode, but the full-scale
range remains the same. Data Hold function can be
cancelled by changing the measurement mode, pressing
RANGE
HOLD
RANGE
RANGE
RANGE key, or push HOLD
HOLD key again.
HOLD
To enter and exit the Data Hold mode:
HOLD
HOLD
1. Press HOLD
HOLD key (short press). Fixes the display on the
current value, "H H H H "" "" "" "" is displayed.
2. A second short press returns the meter to normal mode.
3.1.2
Manual
ranging
and
Autorange
3.1.2 Manual
3.1.2
3.1.2
Manual ranging
Manual
ranging
ranging and
and
and Autorange
Autorange mode
Autorange
The Meter has both manual ranging and autorange
options.
* In the autorange mode, the Meter selects the best range
for the input detected. This allows you to switch test
points without having to reset the range.
* In the manual ranging mode, you select the range. This
allows you to override autorange and lock the meter in a
specific range.
* The Meter defaults to the autorange mode in
measurement functions that have more than one range.
When the Meter is in the autorange mode, AUTO
displayed.
To enter and exit the manual range mode:
RANGE
1. Press RANGE
RANGE key. The Meter enters the manual
RANGE
ranging mode. AUTO
AUTO
AUTO
AUTO turns off. Each presses of RANGE
key increments the range. When the highest range is
reached, the Meter wraps to the lowest range.
mode
mode
mode
AUTO is
AUTO
AUTO
RANGE
RANGE
RANGE
12

Hide quick links:

Advertisement

Table of Contents
loading