CONTINUED FRAMING AND INSTALLATION
CONSTRUCTION
FRAMING
2. The 80ZC cabinet exterior roof or chase framing as follows:
NOTE: No floor protector or finished hearth is needed directly under the Model 80ZC Cabinet, only the
hearth protector is needed.
WARNING:
Install the hearth protector or finished hearth extension only as specified. The exten-
sion must extend a minimum of 16" in front of the stove door opening and must be 47 1/2" wide mini-
mum. Refer to (Page 6) for calculation of R, and K values.
EXTERIOR ROOF OR CHASE
FIGURE 18
47 1/2"
41 1/2"
CHIMNEY
STORM COLLAR
ROOF FLASHING
CHIMNEY PIPE
USE FIRE CODE SHEET ROCK
2" X 4" STUDDING
DOUBLE HEADER: A DOUBLE HEADER
MUST BE USED ON A LOAD BEARING WALL.
THIS MUST BE DONE 12"
ABOVE CABINET.
SINGLE HEADER: A SINGLE HEADER MUST BE
USED AS PAT OF FRONT FRAMING. VERTICAL
2" X 4"'s MUST BE TURNED FLAT.
(See Page 19).