Integration With Hvac Blower Motor - Webasto BlueHeat Installation Instructions Manual

For lexus 2004 rx330
Hide thumbs Also See for BlueHeat:
Table of Contents

Advertisement

Integration with HVAC Blower Motor

ATTENTION
It is permissible to cut excess length from blower control
wiring harnesses.
Position 1 and 2
– Locate vehicle blower motor under passenger side of
vehicle dash.
– Locate blower motor harness connector, cut blower
HVAC
motor positive and negative wires approximately 2
Blower
inches from connector.
Control
– Mount K3 relay under dash (Image not available).
Harness
Integration
Make HVAC Blower wiring connections as follows:
Position 3
– Cut, strip and crimp
Position 4
– Cut, strip and crimp
Position 5
– Cut, strip and crimp
Position 6
– Cut, strip and crimp
Position 7
– Connect to chassis ground
Position 8
– Crimp green wire to green wire
ATTENTION
Check your wiring! Ensure that all connections have
been done in accordance with the accompanying wiring
diagram (Fig. 13). Sensitive electronic controls can be
damaged if wired incorrectly!
Additional
– Secure HVAC blower control wiring to vehicle
structures with nylon wire ties (Image not available)
2004 Lexus RX330 3.3 Liter V-6
Fig. 12
8
Fig. 13
Legend for Figure 6
A From Webasto Heater X1
B 12 VDC ignition 'On' fuse tap
C HVAC control module
M HVAC blower motor
X Cut wire 50 mm (2 in.) from HVAC motor
F3 Fuse - Blower circuit 25 amp.
K1 Relay - Ignition 'On' interrupt
K2 Relay - Positive side of blower motor circuit
K3 Relay - Negative side of blower motor circuit
R1 Resistor - Blower speed control
30 Battery Positive (Constant power)
15 Ignition (Switched power)
31 Battery Negative (Chassis ground)
4
3
4
5
6
7
1
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents