b) G3 signal transmission test
The G3 signal transmission test menu is selected by pressing the numeric key 4 or
NCU test menu. The G3 signals below are sent from the modem using the modular jack and the speaker. The
frequency can be changed with the numeric key.
NOTE:
The transmission level for each frequency follows the service data.
c) V.34 G3 signal transmission test
The V.34 G3 signal transmission test menu is selected by pressing the numeric key 8
NCU test menu. The V.34 G3 signals below are sent from the modem using the modular jack and the speaker by
pressing the Start key. The Baud rate can be changed with the numeric keys, and the Speed can be changed with the
search keys.
5-34
Download Service Manual And Resetter Printer at http://printer1.blogspot.com
T-5-8
Numeric key
0
1
2
3
4
5
6
7
8
T-5-9
Numeric key
0
1
2
3
and
keys from the MODEM
Speed
300 bps
2400 bps
4800 bps
7200 bps
9600 bps
TC7200 bps
TC9600 bps
12000 bps
1440 bps
and
keys from the MODEM
Baud rate
3429 baud
3200 baud
3000 baud
2800 baud