Canon MultiPASS MP390 Service Manual page 112

Hide thumbs Also See for MultiPASS MP390:
Table of Contents

Advertisement

No.
Tx or Rx
##673
[RX]
##674
[TX]
##675
[RX]
##750
[TX]
##752
[TX]
##753
[TX]
##754
[TX]
##755
[TX]
##757
[TX]
##758
[TX]
##759
[TX]
##760
[TX]
##762
[TX]
##763
[TX]
##764
[TX]
Download Service Manual And Resetter Printer at http://printer1.blogspot.com
Definition
In V.34 reception, the procedure fails to move from phase 2 to phase 3
and later, causing a T1 time-over condition
In V.34 transmission, the procedure fails to move from phase 3 or phase
4 to a control channel or later, causing a T1 time-over condition
In V.34 reception, the procedure fails to move from phase 3 or phase 4
to a control channel or later, causing a T1 time-over condition
In ECM transmission, no significant signal can be received after
transmission of PPS-NULL, and the allowed number of procedure signal
re-transmissions was exceeded
In ECM transmission, DCN was received after transmission of PPS-
NULL
In ECM transmission, the allowed number of procedure signal re-
transmissions was exceeded or a T5 time-over (60 sec) condition
occurred after transmission of PPS-NULL
In ECM transmission, the allowed number of procedure signal re-
transmissions was exceeded after transmission of PPS-NULL
In ECM transmission, no significant signal can be received after
transmission of PPS-MPS, and the allowed number of procedure signal
re-transmissions was exceeded
In ECM transmission, DCN was received after transmission of PPS-MPS
In ECM transmission, the allowed number of procedure signal re-
transmissions was exceeded or a T5 time-over (60 sec) condition
occurred after transmission of PPS-MPS
In ECM transmission, the allowed number of procedure signal re-
transmissions was exceeded after transmission of PPS-MPS
In ECM transmission, no significant signal can be received after
transmission of PPS-EOM, and the allowed number of procedure signal
re-transmissions was exceeded
In ECM transmission, DCN was received after transmission of PPS-
EOM
In ECM transmission, the allowed number of procedure signal re-
transmissions was exceeded or a T5 time-over (60 sec) condition
occurred after transmission of PPS-EOM
In ECM transmission, the allowed number of procedure signal re-
transmissions was exceeded after transmission of PPS-EOM