Figure 8
Simplified wiring diagrams
6
NOTES:
(1) Power Supply; 24volts (RMS or DC) nominal or less
(2) Door Device: current not to exceed 5A
(3) Connect a power supply output lead to the equipment
ground if not already connected
See diagram below
for proper wire connections
To common
Ground wire #18 AWG (10 MWG)
Orange
White
Wall
Mount
System
Black
Green/
Yellow
Wire connection diagram
Stanley Omnilock
a Product Group of Stanley Security Solutions, Inc.
+
-
System diagram
Fail safe
Fail secure
See note 1
-
Power
Supply
+
See
note 2
Exit
Device
-
Power
supply
(24V max)
+
+
Device
(5A max)
-