Installation Instructions for Stanley Omnilock Wall Mount Units
Installation Instructions for Stanley Omnilock Wall Mount Units
Install outside escutcheon
5
Optional: Install Extreme
Weatherized Unit, if necessary
Note: Ensure that the external system power
supply is turned off.
Note 2: See Caution in Section 4 on page 4.
1 Thread the connecting cables through the wire
access hole from the outside wall to the inside
wall.
2 Secure the escutcheon to the wall with the
screws and anchors provided. Ensure no wires are
pinched when attaching the escutcheon to the
wall.
3 Route the connecting cables, power supply,
device and grounding wire through the wire
access hole drilled in the inside wall. Allow
approximately 4 inches of wire to protrude from
the wall. See Figure 6.
Note: If using a remote switch, also route the
twisted pair wires through the access hole and
attach to the terminal block. (Not available for
wireless units.)
4 Attach the inside wall mount unit to the wall with
the proper screws and anchors for the wall
material.
5 Plug the connecting cables into the circuit board
as shown in Figure 7.
6 Use the wire nuts provided to connect the wall
mount wires to the system wires. Place wire nuts
on any unused wires. See Figure 8.
7 Install batteries with proper polarity as shown in
Figure 7.
8 Press and hold the reset button on the circuit
board (as shown in Figure 7) until the green light
on the escutcheon keypad flashes (about three
seconds) then release the button.
9 Tuck the wires and wire nuts into the housing and
screw on cover.
Figure 6
Terminal block
(not available
on wireless
models)
Connecting
cables
Wire nuts
Figure 7
Stanley Omnilock
a Product Group of Stanley Security Solutions, Inc.
External wiring
Connecting cables
Installing the Extreme Weatherized unit
Extreme Weatherized circuit board
Inside wall
mount
Reset button
Batteries
Relay
Ground
5