(8)Removing and replacing the stepping motor and temperature/humidity sensor
①
(7)Removing the rear casing)
②Remove the connector P20 and stepping
motor setscrews(2) to remove the stepping
stepping motor)
③Remove the connector P10 and tape to
separate the lead wire from the blower fan
guide casing.
④Detach the catch(1) from the blower fan
assembly to remove the
and replacing the temperature/humidity
sensor)
(9)Removing and replacing the solenoid valve and plug cord
①Remove the rear casing.
rear casing)
②Remove the connector P3 from the
power control board and remove
the solenoid valve setscrew(1) to
remove the solenoid valve.
solenoid valve)
③Remove the earth wire setscrew(1)
to remove the earth wire.
④Remove the connector P1 and
separate the power plug cord wire
from the clamper to remove the
power plug from the gap of the
the plug cord)
Temperature/humidity sensor
Blower fan assembly Catch
④
Drainpan assembly
②
④
Solenoid valve Solenoid valve setscrew
③
Earth wire setscrew
②
③
Stepping motor setscrews
②
Blower fan assembly
③
④
Drainpan assembly
Connector(P1)
Connector(P3)
Earth wire
Connector(P10)
Connector(P20)
Stepping motor
Blower fan assembly
Blower fan assembly
④
Temperature/humidity sensor
④
Plug cord
Gap
Base
27