Mitsubishi Electric MJ-E14CG-S1-IT Service Manual page 27

Table of Contents

Advertisement

(8)Removing and replacing the stepping motor and temperature/humidity sensor
(7)Removing the rear casing)
②Remove the connector P20 and stepping
motor setscrews(2) to remove the stepping
stepping motor)
③Remove the connector P10 and tape to
separate the lead wire from the blower fan
guide casing.
④Detach the catch(1) from the blower fan
assembly to remove the
and replacing the temperature/humidity
sensor)
(9)Removing and replacing the solenoid valve and plug cord
①Remove the rear casing.
rear casing)
②Remove the connector P3 from the
power control board and remove
the solenoid valve setscrew(1) to
remove the solenoid valve.
solenoid valve)
③Remove the earth wire setscrew(1)
to remove the earth wire.
④Remove the connector P1 and
separate the power plug cord wire
from the clamper to remove the
power plug from the gap of the
the plug cord)
Temperature/humidity sensor
Blower fan assembly Catch
Drainpan assembly
Solenoid valve Solenoid valve setscrew
Earth wire setscrew
Stepping motor setscrews
Blower fan assembly
Drainpan assembly
Connector(P1)
Connector(P3)
Earth wire
Connector(P10)
Connector(P20)
Stepping motor
Blower fan assembly
Blower fan assembly
Temperature/humidity sensor
Plug cord
Gap
Base
27