ZONES TO BE MONITORED

******************************************************************************************************
Any zone can be selected for operation in
Monitor mode. However, do not select a zone
that has been installed to generate a 24 hour
alarm (eg. Fire Detector).
To remove a zone from the Monitor mode
selection, re-enter the zone number.
To VIEW Zones to be monitored ENTER
(PROG) (8) (END)

ZONES TO CONTROL THE AUXILIARY OUTPUT

******************************************************************************************************
The 8 Zone Control Panel provides an Auxiliary
output which can be turned on and off by ANY
selected zones or via the keypad. This output
can be used for a variety of applications. Talk
to your security installation company about
your specific requirements.
A zone programmed for Auxiliary will cause the
Auxiliary Output to turn on when it becomes
unsecured, regardless of whether the Panel is
Armed or Disarmed.
To remove a zone from the selection, re-enter
the zone number of the zone to be removed.
To VIEW Auxiliary Zones ENTER
(PROG) (9) (END)

PROGRAMMING SUMMARY

******************************************************************************************************
DESCRIPTION
Code 1
Code 2
Code 3
Code 4
Entry Delay Time
Exit Delay Time
Monitor Type
Monitor Zones
Aux Output Zones
OPTION
P1E code E code E
P2E code E code E
P3E code E code E
P4E code E code E
P5E time E
P6E time E
P7E type E
P6E zone E
P9E zone E
To program, say, zones 3 and 4 to be
Monitor zones, enter,
P8E 2E 3E 4E
As each zone is programmed, the
corresponding zone light is illuminated (if it was
previously off). If the zone light was previously
on, it will be extinguished, thus de-selecting that
zone from Monitor mode.
To CHANGE zones to be monitored ENTER
(ZONE NUMBER) (END)
To program, say, zones 4, 6 and 8 to control
the Auxiliary Output, enter:
P9E 4E 6E 8E
As each zone is programmed, the
corresponding zone light is illuminated (if it was
previously off). If the zone light was previously
on, it will be extinguished, thus de-selecting
that zone.
The output can also be turned on or off
(toggled) by pressing 9 E while Disarmed or
in Monitor mode.
To CHANGE Auxiliary Zone(s) ENTER.
(ZONE NUMBER) (END)
DEFAULT
20 secs
60 secs
Type 2
All Zones
All Zones
PROGRAMMED
(1-99)
(1-99)
(1-4)
(1-8)
(1-8)
9