Access Codes; Entry Delay Time - Ness Security Products 5000 SERIES Instruction Manual

Table of Contents

Advertisement

ACCESS CODES ***********************************************************************************************

The control Panel may be programmed with up
to 4 separate Access Codes. Therefore each
user may be allocated with their own unique
code for higher security.
REMEMBER
Access CODE 1 (master code) MUST
be programmed.
All codes must contain a minimum of 3
digits to a maximum of 6 digits and
must not begin with a zero.
Codes 2,3 and 4 are optional.
A code may be cancelled by beginning
the code with zero.
As a security measure, the existing
code will not be displayed and the new
code must be entered twice. If the
second entry differs from the first, the
existing code will remain unchanged.
To input Code 1 ENTER
(PROG) (1) (END) (_ _ _ _ ) (END) (_ _ _ _ ) (END)
(_ _ _ _ ) Represents the numbers required as the code.
To input Code 2 ENTER
(PROG) (2) (END) (_ _ _ _ ) (END) (_ _ _ _ ) (END)
(_ _ _ _ ) Represents the numbers required as the code.
Access Codes 3 and 4 are programmed as above.

ENTRY DELAY TIME

******************************************************************************************************
The Entry Delay Time is the time the Control
Panel gives you to disarm the Panel after a
delay zone is unsecured.
For maximum security, the Entry Delay Time
should be as short as possible.
The Entry Delay Time can be set to a minimum
of 1 second up to a maximum of 99 seconds.
To VIEW the Entry Delay Time ENTER
(PROG) (5) (END)
1) To program code 1 to be, say, 3456, then
enter:
P 1 E 3456 E 3456 E
2) To program code 2 to be, say, 9765, then
enter:
P 2 E 9765 E 9765 E
3) To CANCEL code 2, then enter:
P 2 E 09765 E 09765 E
1. To view the current Entry Delay Time, enter:
P5E
2. The value programmed will be displayed via
the zone (1-8), battery (9) and mains (0)
lights. The display of the current value must
be complete before a new value can be
entered.
3. To change the current value to say,
10 seconds enter:
10 E
Zone 1 light will flash on for 1 second followed
by the MAINS light (0) to indicate the new value
To CHANGE the Entry Delay Time ENTER
(VALUE) (END)