EXIT DELAY TIME

******************************************************************************************************
The Exit Delay Time is the time the Control
Panel gives you to secure and depart the
premises after the Panel is Armed.
The Exit Delay Time should be just long enough
to allow departure comfortably without rushing
and making mistakes.
The Exit Delay Time can be set to a minimum of
1 second up to a maximum of 99 seconds.
To VIEW Exit Delay Time ENTER
(PROG) (6) (END)
MONITOR MODE 'TYPE
******************************************************************************************************
The 8 zone Control Panel provides an unique
Monitor mode to ensure your security even
while the Panel is disarmed and the premises
are occupied.
Typically, Monitor mode is used to monitor the
perimeter zones (doors, windows) of a house
while the occupants are at home or to monitor
entry through front doors or fire doors in shops
and offices while the premises are in use.
You can program which zones are to be
monitored as well as select 1 of 4 different
types of Monitor alarms.
To VIEW Monitor Mode Type ENTER
(PROG) (7) (END)
1. To view the current Exit Delay Time, enter:
P 6E
2. The value programmed will be displayed via
the zone (1-8), battery (9) and mains (0)
lights. This display of the current value must
be complete before a new value can be
entered.
3. To change the current value to say,
80 seconds enter:
80 E
Zone 8 light will flash on for 1 second followed
by the MAINS light (0) to indicate the new value
To CHANGE Exit Delay Time ENTER
(VALUE) (END)
The 4 different types of Monitor mode alarms
are:
1 = Beeper warning for the duration of the panel
entry time, then full siren alarm. Used for
perimeter protection.
2 = Beeper and siren operate for 2 seconds
only. Use this for medium security warnings or
as a walk test mode.
3 = Full siren alarm immediately. Use this for
high security, such as monitoring fire doors etc.
4 = Zone number is beeped out only. Use this
for door opened warning.
To select, say, Monitor mode 3, enter:
P7E 3E
When the above option is programmed into the
panel, zone light 3 will flash on for 1 second.
Talk to your security installation company
about your specific requirements.
To CHANGE Monitor Mode Type ENTER
(VALUE) (END)