About this document This document contains instructions for the installation of SISTORE MX and SISTORE MX 3G units. For information on configuration please refer to the Configuration Manual. For information on operation please refer to the User Manual.
Trigger and digital inputs.................19 6.2.4 Digital outputs ..................19 Behaviour with overheating..............20 Description of SISTORE MX 3G / MX 3G DVD........21 Connections und displays on the front side of the device ......21 Connections on the back of the device...........22 7.2.1 Trigger and digital inputs.................23 7.2.2...
Page 4
Subsequent installation of software components........54 Software (SISTORE RemoteView ............56 10.1 System requirements ................56 10.2 Installing SISTORE RemoteView............57 10.3 Updating SISTORE RemoteView ............59 10.4 Subsequent installation of software components........60 System limits ..................60 Disposal ....................60 Siemens Building Technologies Fire Safety & Security Products 02.2009...
This is a Class A device. This equipment may cause radio interference in a residential installation. In this case the user is encouraged to perform appropriate measures to correct the interference. Siemens Building Technologies Fire Safety & Security Products 02.2009...
There is a risk of minor to medium injuries or damage to property. IMPORTANT Malfunctioning may result Meaning of the hazard symbols The nature of the hazard is indicated by icons. Warning of a hazard Siemens Building Technologies Fire Safety & Security Products 02.2009...
EU directives EU directives This product complies with the requirements of the following European directives. The EU declaration of conformity is available to the responsible agencies at: Siemens Building Technologies Fire & Security Products GmbH & Co. oHG 76187 Karlsruhe Germany European Directive 2004/108/EC „Electromagnetic Compatibility”...
Technical data Technical data SISTORE MX / MX DVD SISTORE MX 3204 SISTORE MX 3208 - 3232 with 4 video inputs with 8, 16 or 32 video inputs Recording speed Max. 50 fps, Max. 100 fps, configurable for analogue cameras configurable for analogue cameras Max.
Page 9
Electrical isolation Up to 2500 V SISTORE MX systems are configured for DHCP by default. If there is no DHCP server in the network, select the menu sequence Administration> Configuration, then click the button TCP/IP parameters in the Network tab and enter a permanent IP address instead of DHCP.
Max.: 4 SATA hard disks (1 TB max. each) Memory capacity SISTORE MX 3G: 1000 – 4000 GB data memory SISTORE MX 3G DVD: 1000 – 3000 GB data memory External storage media Via network connection Display resolution 1024 x 768, 1280 x 1024, 1920 x 1200...
Page 11
Electrical isolation Up to 2500 V SISTORE MX systems are configured for DHCP by default. If there is no DHCP server in the network, select the menu sequence Administration> Configuration, then click the button TCP/IP parameters in the Network tab and enter a permanent IP address instead of DHCP.
100 ips analog, 100 ips digital, with DVD * Unit incl. packing material, accessories that are included in the delivery, and documentation All SISTORE MX models have enabled video output and SCSI functions and are delivered without keyboard. The part number (PN) of your SISTORE unit will be found on the rating plate on the bottom of the unit.
Page 13
1.2 kg (GAA/ATM) cash box or access control systems SISTORE MX hard drive 2GF4811-8CD For the expansion of SISTORE MX as of V2.50 0.8 kg expansion kit 250 GByte SISTORE MX hard drive S24245-B5093-A1 For the expansion of SISTORE MX as of V2.50 0.8 kg...
11.7 kg * Unit incl. packing material, accessories that are included in the delivery, and documentation All SISTORE MX models have enabled video output functions and are delivered without keyboard. The part number (PN) of your SISTORE unit will be found on the rating plate on the bottom of the unit.
SISTORE unit Mouse Mains cable 8 x digital I/O connector (SISTORE MX 3204) 14 x digital I/O connector (SISTORE MX 3208 - 3232) Activation form CD with the SISTORE MX application software and complete documentation Installation Manual SISTORE MX 3G / MX 3G DVD...
Description of SISTORE MX / MX DVD Connections und displays on the front side of the device Fig. 1 Front side of SISTORE MX 3204 and SISTORE MX 3208 - 3232 LED displays on the front side of the device Power...
Description of SISTORE MX / MX DVD Connections on the back of the device 6.2.1 SISTORE MX 3204 8 9 10 Fig. 2 Back side of SISTORE MX 3204 Video output 2 video outputs, 50 Hz/60 Hz Connect the same type of unit here as that on the video inputs (PAL, for example), since otherwise it is not possible to operate the video outputs.
SISTORE MX 3208 - 3232 8 9 10 Fig. 3 Back side of SISTORE MX 3208 - 3232 Video output 4 video outputs, 50 Hz/60 Hz Connect the same type of unit here as that on the video inputs (PAL, for example), since otherwise it is not possible to operate the video outputs.
Trigger and digital inputs The HVR is equipped with optocoupler that run the TTL-compatible trigger inputs of the SISTORE MX via optocoupler and enable the switching of signal levels up to 24 V. The inputs of the optocoupler are designed for a voltage range of 5 to 24 V.
Description of SISTORE MX / MX DVD Behaviour with overheating If the Error LED on the front of the device lights yellow, there are two possible causes: Overheating of the hard drive The running application cannot be stopped. A new application cannot be started.
Description of SISTORE MX 3G / MX 3G DVD Connections und displays on the front side of the device Fig. 6 Front side of SISTORE MX 3G / MX 3G DVD LED indicators when the device is switched on Video inputs 1 – 16...
Connections on the back of the device Fig. 7 Back side of SISTORE MX 3G / MX 3G DVD Damage to the device and impairment of electrical safety When voltages are applied to the digital inputs/outputs the device may be damaged and electrical safety may be impaired.
Description of SISTORE MX 3G / MX 3G DVD 7.2.1 Trigger and digital inputs The HVR is equipped with optocouplers that enable the connection of floating contacts. The contacts will be triggered when the inputs are shorted. The switching voltage of the switches is 5 V ±10 %, with a max. switching current of 5 mA.
Place the device on the mounting rails and push it into the cabinet. Attach the unit with the four M6x18 screws and plastic washers to the mounting rails of the network cabinet (see F ig. 10). 7 6 H Siemens Building Technologies Fire Safety & Security Products 02.2009...
Installation Setting DIP switches (SISTORE MX / MX DVD) Fig. 11 DIP switches All DIP switches are set to on by default, i.e. the video inputs are terminated with 75 Ohm. If the signals are to be looped through the DIP switches must be set to off.
D escription of SISTORE 7 9 H 8 0 H MX / MX DVD or Section D escription of SISTORE MX 3G / MX 3G DVD. 8 1 H 8 2 H Siemens Building Technologies Fire Safety & Security Products...
D escription of SISTORE 8 3 H 8 4 H MX / MX DVD or Section D escription of SISTORE MX 3G / MX 3G DVD. 8 5 H 8 6 H Prerequisite: The CKA driver is installed and the icon is displayed in the task bar.
D escription of SISTORE 9 3 H 9 4 H MX / MX DVD or Section D escription of SISTORE MX 3G / MX 3G DVD. 9 5 H 9 6 H Prerequisite: The CKA driver is installed and the icon is displayed in the task bar.
D escription of SISTORE 1 0 0 H 1 0 1 H MX / MX DVD or Section D escription of SISTORE MX 3G / MX 3G DVD. 1 0 2 H 1 0 3 H Prerequisite: The CKA driver is installed and the icon is displayed in the task bar.
D escription of SISTORE 1 0 9 H 1 1 0 H MX / MX DVD or Section D escription of SISTORE MX 3G / MX 3G DVD. 1 1 1 H 1 1 2 H Prerequisite: The CKA driver is installed and the icon is displayed in the task bar.
1 1 7 H 1 1 8 H Siemens Building Technologies Fire & Security Products GmbH & Co. oHG. It can be ordered from Contour Design Ltd. (www.contourdesign.com) (product name: ShuttlePRO2). The Multimedia Control Panel has been integrated and tested with SISTORE MX. Siemens Building Technologies Fire &...
Page 34
1 1 9 H 1 2 0 H MX / MX DVD or Section D escription of SISTORE MX 3G / MX 3G DVD. 1 2 1 H 1 2 2 H Installing the software for the Multimedia Control Panel...
Page 35
Installation The following dialog box opens. Click LAUNCH SETUP. The following dialog box opens. Click Next. Siemens Building Technologies Fire Safety & Security Products 02.2009...
Page 36
Yes, I agree with all the terms of this license agreement Click Next The following dialog box opens. Click Next to install the software in the default directory. The following dialog box opens. Siemens Building Technologies Fire Safety & Security Products 02.2009...
Page 37
The software will be installed. The following dialog box opens. 11. Mark the checkbox Open the Contour Control Panel. 12. Click Finish. The software has been installed. dialog box appears. Contour Shuttle Device Configuration Siemens Building Technologies Fire Safety & Security Products 02.2009...
Page 38
Installation Configuring the Multimedia Control Panel Fig. 19 Contour Shuttle Device Configuration Click Options. The following context menu will open: Select Import settings in the context menu. Siemens Building Technologies Fire Safety & Security Products 02.2009...
Page 39
The Multimedia Control Panel is ready for operation. Information on the operation of the SISTORE MX, SISTORE RemoteView and SISTORE Player application software using the Multimedia Control Panel can be found in the SISTORE MX User Manual. Siemens Building Technologies Fire Safety &...
Install the Siemens LAN camera CCIx1345. Further information on this can be found in the installation manual for the camera. Configure alarm activation for the Siemens LAN camera CCIx1345. Further information on this can be found in the SISTORE MX Configuration Manual. Siemens Building Technologies Fire Safety & Security Products...
Choose the camera type from the first list box. Choose the interface from the second list box. Click Apply. The interface for the dome camera is enabled. Further information on this can be found in the SISTORE MX Configuration Manual. Connections Signal...
Choose the interface from the second list box. 10. Click Apply. The interface for the dome camera is enabled. Further information on this can be found in the SISTORE MX Configuration Manual. Siemens Building Technologies Fire Safety & Security Products...
Choose the camera type from the first list box. Choose the interface from the second list box. Click Apply. The interface for the camera is enabled. Further information on this can be found in the SISTORE MX Configuration Manual. Connections Signal...
Choose the camera type from the first list box. Choose the interface from the second list box. Click Apply. The interface for the camera is enabled. Further information on this can be found in the SISTORE MX Configuration Manual. 8.4.9 Connecting SCU pan-and-tilt unit PT40P via controller CDC050x...
1 5 8 H 1 5 9 H MX / MX DVD or Section D escription of SISTORE MX 3G / MX 3G DVD. 1 6 0 H 1 6 1 H Connect the pan-and-tilt units via controller CDCD2417 to the RS485 port (COM2) of the SISTORE (see F ig.
For a more detailed description of the connections please refer to Section 6 Description of SISTORE MX / MX DVD or Section 7 Description of SISTORE MX 3G / MX 3G DVD. Connect the MX Multi-Channel Box to the SISTORE unit (see Fig. 27).
1 6 8 H 1 6 9 H MX / MX DVD or Section D escription of SISTORE MX 3G / MX 3G DVD. 1 7 0 H 1 7 1 H Connect the MX Multi-Channel Box to the SISTORE (see F ig.
For a more detailed description of the connections please refer to Section 6 Description of SISTORE MX / MX DVD or Section 7 Description of SISTORE MX 3G / MX 3G DVD. Connect the MX Multi-Channel Box(es) to the SISTORE unit (see Fig. 30).
Installation 8.4.14 SISTORE unit – CKA4820 – SISTORE RemoteView – LAN cameras Fig. 31 SISTORE MX – CKA4820 – SISTORE RemoteView – LAN cameras system overview CKA4820 optional SISTORE unit Client PC with RemoteView SISTORE MX: max. 64 LAN cameras various manufacturers SISTORE MX 3G: max.
Page 51
Installation CKA4820 interface configuration Protocol: SIMATRIX RS232 or SIEMENS IVM Baud rate: 9600 Parity: None If you want to connect the CKA4820 control panel to a SISTORE via the internal COM1A interface, install the RS-232C/RS-485 interface converter into the connection line (see F ig.
If you run an active virus scan, the recording process may be stopped, resulting IMPORTANT in a loss of data. Run the virus scan after recording has stopped. Software operation using the virtual keyboard Fig. 32 Password entry using the virtual keyboard Siemens Building Technologies Fire Safety & Security Products 02.2009...
Entries into all other input fields of the system are made in the same manner. Updating or repairing software You may have to reinstall or repair the SISTORE MX application software on a SISTORE unit or on a client PC in case components of the software are damaged.
IMPORTANT Install only software products on the SISTORE that have been approved by the manufacturer. Software components of the SISTORE MX application software can be subsequently installed on the SISTORE unit. Place the installation CD in the CD drive. Launch SISTORE_MX_280.exe.
Page 55
Mark the appropriate checkbox(es). Click Next. The following dialog box opens. Select the option Yes, I want to restart my computer now. Click on Finish. The selected software component has been installed. Siemens Building Technologies Fire Safety & Security Products 02.2009...
Min. 2 USB ports (2.0) Internet Explorer 6.x or higher Monitor with min. 17-inch screen Display resolution 1024 x 768 or 1280 x 1024 pixels Optional: Laser printer or inkjet printer Optional: CD/DVD burner Siemens Building Technologies Fire Safety & Security Products 02.2009...
Launch the file SISTORE_MX_RemoteView_280.exe by double clicking on it. The following dialog box opens. Select the desired language and click OK. The following dialog box opens. Click Next. Siemens Building Technologies Fire Safety & Security Products 02.2009...
Page 58
The following dialog box opens. Click Next. The following dialog box opens. Select RemoteView and click Next. The Select program folder dialog box opens. Do not change the destination folder. Click Next. Siemens Building Technologies Fire Safety & Security Products 02.2009...
Launch the file SISTORE_MX_RemoteView_280.exe. The following dialog box opens. Select the option Update. Click Next. The update will be performed automatically. It is not necessary to restart your computer after completion of the update. Siemens Building Technologies Fire Safety & Security Products 02.2009...
..Fig. 33 SISTORE MX system in multi-server mode Up to 32 analog camera can be connected to each SISTORE unit. Each SISTORE unit can connect to up to 64 LAN cameras. Each SISTORE RemoteView station can connect to up to 10 SISTORE units at the same time.