Dimensions; Minimum Clearances; Clearance From Combustible Components; Using The Installation Template - Vaillant ecoTEC plus Installation And Maintenance Instructions Manual

Table of Contents

Advertisement

4 Installation
4.4

Dimensions

183,5
33,5
78
220
1
Condensate discharge
2
Gas connection
3
Heating return
8
1
2
71
375
3
4
5
4
Heating flow
5
Flue pipe connection
4.5

Minimum clearances

C
C
A
B
C
D
4.6

Clearance from combustible components

It is not necessary to maintain a clearance between the
product and components made of combustible materials.
4.7

Using the installation template

Use the installation template to ascertain the locations at
which you need to drill holes and make breakthroughs.
4.8

Wall-mounting the product

A
B
1.
Check whether the wall has sufficient load-bearing ca-
pacity to bear the operational weight of the product.
2.
Check if the supplied fixing material may be used for
the wall.
Conditions: The load-bearing capacity of the wall is sufficient, The fixing
material may be used for the wall
Wall-mount the product as described.
Conditions: The load-bearing capacity of the wall is not sufficient
Ensure that wall-mounting apparatus on-site has a suf-
ficient load-bearing capacity. Use individual stands or
primary walling, for example.
Installation and maintenance instructions ecoTEC plus 0020200871_00
D
Minimum clearance
150 mm
150 mm
5 mm
600 mm