Setting level
d.58 Solar circuit reheating
d.60 Number of blocks by the
temperature sensor
d.61 Number of successful
ignitions
d.62 Night set-back
d.64 Average burner ignition
time
d.65 Maximum burner ignition
time
d.66 Activation of the warm
start function for hot water
d.67 Remaining burner anti-
cycling time (setting under
d.02)
d.68 Number of unsuccessful
ignitions at 1st attempt
d.69 Number of unsuccessful
ignitions at 2nd attempt
d.71 Maximum heating flow set
target temperature
d.75 Maximum cylinder reheat-
ing time
d.77 Max. cylinder reheating
d.78 DHW max. flow temperat-
ure
d.80 Running time in heating
mode
d.81 Running time in DHW
mode
d.82 Number of burner igni-
tions in heating mode
d.83 Number of burner igni-
tions in DHW mode
d.84 Maintenance in
d.85 Increase in the min. out-
put (heating and DHW mode)
d.90 Status of the eBUS room
thermostat
d.93 Setting the product code
d.94 Delete fault list
d.95 Software versions
d.96 Reset to factory setting
d.128 Heating minimum target
value
0020200871_00 ecoTEC plus Installation and maintenance instructions
Values
Unit
Min.
Max.
0
3
Current value
Current value
0
30
Current value
s
Current value
s
Current value
min
Current value
Current value
45
80
20
90
min
kW
50
80
Current value
h
Current value
h
Current value
Current value
0
3000
h
kW
Current value
0
99
0
1
10
75
Increment, select, explanation
0 = Boiler's Legionella protection
function deactivated
3 = Hot water activated (target value
min. 60 °C)
1
off = Function deactivated
on = Function activated
1
1
1
→ Section "Technical data"
1
Number of ignitions = Display value x
100
Number of ignitions = Display value x
100
Number of hours = Display value x 10
1
→ Section "Technical data"
off = Not connected
on = Connected
1
off = No
on = Yes
1 = Main PCB
2 = Interface PCB
0 = No
1 = Yes
1
Appendix
Default set-
Own setting
ting
0
Adjustable
Not
adjustable
Not
adjustable
0
Adjustable
Not
adjustable
Not
adjustable
1
Adjustable
Not
adjustable
Not
adjustable
Not
adjustable
75
Adjustable
45
Adjustable
Adjustable
Adjustable
Not
adjustable
Not
adjustable
Not
adjustable
Not
adjustable
300
Not
adjustable
Adjustable
Not
adjustable
Adjustable
Adjustable
Adjustable
Adjustable
10
Adjustable
27