E Overview Of Fault Codes - Vaillant ecoTEC plus Installation And Maintenance Instructions Manual

Table of Contents

Advertisement

E
Overview of fault codes
Code
Meaning
F.00
Flow temperature sensor interruption
F.01
Return temperature sensor interruption
F.10
Flow NTC short circuit
F.11
Return NTC short circuit
F.13
Warm start sensor/cylinder sensor short circuit
F.22
Safety switch-off: Low water pressure
F.23
Safety switch-off: Temperature difference too
great
F.24
Safety switch-off: Temperature rise too fast
F.25
Safety switch-off: Flue gas temperature too high
F.27
Safety switch-off: Flame simulation
F.28
Failure during start-up: Ignition unsuccessful
F.29
Failure during operation: Re-ignition unsuccess-
ful
F.32
Fan fault
F.49
Fault: eBUS
F.61
Fault: Gas valve regulation
F.62
Fault: Gas valve switch-off delay
F.63
Fault: EEPROM
F.64
Fault: Electronics/NTC
F.65
Fault: Electronics temp.
F.67
Fault: Electronics/flame
F.68
Fault: Unstable flame signal
F.70
Invalid device specific number (DSN)
F.71
Flow NTC fault
F.72
Flow/return NTC fault
0020200871_00 ecoTEC plus Installation and maintenance instructions
Cause
NTC plug not plugged in or has come loose, multiple plug on the PCB
not plugged in correctly, interruption in cable harness, NTC defective
NTC plug not plugged in or has come loose, multiple plug on the PCB
not plugged in correctly, interruption in cable harness, NTC defective
NTC defective, short circuit in cable harness, cable/casing
NTC defective, short circuit in cable harness, cable/casing
NTC defective, short circuit in cable harness, cable/casing
No or insufficient water in the product, water pressure sensor defective,
cable to pump or water pressure sensor loose/not connected/defective
Pump blocked, insufficient pump output, air in product, flow and return
NTC connected the wrong way round
Pump blocked, insufficient pump output, air in product, system pressure
too low, non-return valve blocked/incorrectly installed
Break in plug connection for optional flue gas safety temperature limiter
(STB), break in cable harness
Moisture on the electronics, electronics (flame monitor) defective, gas
solenoid valve leaking
Gas meter defective or gas pressure monitor has triggered, air in gas,
gas flow pressure too low, thermal isolator device (TAE) has triggered,
condensate duct blocked, incorrect gas restrictor, incorrect spare part
gas valve, fault on the gas valve, multiple plug on PCB incorrectly
plugged in, break in cable harness, ignition system (ignition transformer,
ignition cable, ignition plug, ignition electrode) defective, ionisation
current interrupted (cable, electrode), incorrect earthing of product,
electronics defective
Gas supply temporarily stopped, flue gas recirculation, condensate duct
blocked, defective earthing of product, ignition transformer has spark
failure
Plug on fan not correctly plugged in, multiple plug on PCB not correctly
plugged in, break in cable harness, fan blocked, Hall sensor defective,
electronics defective
Short circuit on eBUS, eBUS overload or two power supplies with differ-
ent polarities on the eBUS
Short circuit/short to earth in cable harness for the gas valve
Gas valve defective (coils shorted to earth)
Electronics defective
Delayed shutdown of gas valve
Delayed extinguishing of flame signal
Gas valve leaking
Electronics defective
Electronics defective
Flow or return NTC short circuited, electronics defective
Electronics overheating due to external influences, electronics defective
Implausible flame signal, electronics defective
Air in gas, gas flow pressure too low, incorrect air ratio, condensate
duct blocked, incorrect gas restrictor, ionisation flow interruption (cable,
electrode), flue gas recirculation, condensate duct
If spare parts fitted: Display and PCB replaced at same time and DSN
not reset, incorrect or missing output range coding resistance
Flow temperature sensor signalling constant value:
Flow temperature sensor incorrectly positioned at supply pipe
Flow temperature sensor defective
Flow/return NTC temperature difference too great → flow and/or return
temperature sensor defective
Appendix