Dimensions; Minimum Clearances; Clearance From Combustible Components; Using The Mounting Template - Vaillant ecoTEC plus VC 406/5-5 Installation And Maintenance Instructions Manual

Table of Contents

Advertisement

4 Set-up
4.3

Dimensions

1
2
100
10
173
120
1
Condensate siphon
2
Heating flow connection
3
Gas connection
4
Heating return connec-
tion
8
3
4
5
100
440
120
6
7
8
9
5
Drain for the rainwater
collecting device
6
Position of the holes for
the flue system
7
Retainer for securing
the product
8
Gas pressure connec-
tion
9
Connection for the
air/flue pipe
Dimension A
VC 406/5-5 (E-DE)
VC 406/5-5 (LL-DE)
VC 476/5-5 (E-DE)
VC 476/5-5 (LL-DE)
VC 636/5-5 (E-DE)
VC 636/5-5 (LL-DE)
4.4

Minimum clearances

C
C
When using the accessories, observe the minimum clear-
ances/installation clearances.
Minimum clearances
A
B
≥ 275 mm
≥ 180 mm
Optimum dimension (B): ≈ 250 mm
Optimum dimension (C): ≈ 50 mm
Dimension (D): The clearance in front of the product
to facilitate easy access for maintenance work can
be reduced to 5 mm if there is a door in front of the
product
4.5

Clearance from combustible components

It is not necessary to maintain a clearance between the
product and components made of combustible materials that
go beyond the minimum clearances.
4.6

Using the mounting template

Use the mounting template to ascertain the locations at
which you need to drill holes and make breakthroughs.
Installation and maintenance instructions ecoTEC plus 0020261188_00
10
Drain for the dynamic
air separation system
405 mm
405 mm
405 mm
405 mm
473 mm
473 mm
D
C
D
≥ 5 mm
≥ 500 mm