In order to erase to ZERO "0" value, press the "2 long coffees" and the "2short coffees" at the
same time in the GROUP 1 (left hand group), following the display will show:
WARNING: The individual counter for each dose (1 short coffee- espresso, 1 long coffee, etc.)
can not be erased.
WARNING: The total coffees erased do not erase the counter of the litters of water wasted.
H. WARNING OF LOW WATER LEVEL IN THE BOILER.
When you are turning on the machine for the first time (General Switch – position 1), the filling
up process begins.
If the level probe do NOT DETECT WATER inside the boiler in 6 seconds, automatically
will cut off the element and stopping the heating process.
The display will show:
In case the machine is normal operation and the level probe notice NO WATER for 3
seconds, automatically will cut off the element and stopping the heating process.
In order to cancel this alarm, you have to fill up the boiler of water; the element will be on and
the machine will continue the heating process after, having noticed water by the level probe for
3 seconds.
MANUAL NEW IBERITAL INGLES
11/05/2007
Total coffees
Boiler
empty
Total cafés