Blade Guard; Dust Chute; Electrical Connections; Grounding Instructions - Powermatic PM1000 RU Operating Instructions And Parts Manual

10-inch cabinet saw
Table of Contents

Advertisement

pawl block down until it securely engages in
notch.
4.
Allow pawls to drop freely to the table.

7.15 Blade guard

Refer to Figure 12.
1.
Push and hold button (J
2.
Push guard (J) down at an angle, as shown,
until pin engages rear slot in riving knife, then
push down front of guard until it seats properly,
and is parallel to table top.
3.
Release button (J
leaves (K) should drop freely to the table.
4.
Lift up on guard assembly to verify proper
seating.
NOTE: The transparent leaves can be kept in
raised position by lifting them up and forward.
Guard and pawl assemblies
must be securely installed, and leaves must be
in contact with table, before beginning any
through-cutting operation.
The bracket and clamp plate (E/F, Figure 12) are
adjusted at the factory and no further adjustment of
the blade guard and riving knife assembly should
be necessary. However, proper alignment is very
important. Before operating table saw, read
section 9.6 ,Riving knife alignment, to verify and
follow adjustment procedure if necessary.

7.16 Dust chute

Use of a dust collection system (not provided) is
strongly recommended during table saw operation.
It will help keep the shop clean, as well as prevent
potential health issues due to dust inhalation.
Attach dust collection hose to the 4-inch dust port
at base of saw, and secure with a wire hose clamp
(not provided).

8.0 Electrical connections

The PM1000 table saw is rated at 230V power for
single phase, 2 HP, and at 380V power for three
phase 3HPt. The table saw comes with a plug
designed for use on a circuit with a grounded outlet
that looks like the one pictured in A, Figure 13.
Before connecting to power source, be sure switch
is in off position.
It is recommended that the table saw, when
operated at 230V, be connected to a dedicated 30
amp circuit with breaker or time-delay fuse marked
"D". When operated at 380 volts, connect the saw
to a dedicated 20 amp circuit with breaker or time-
) at back end of guard.
1
). The transparent guard
1
delay fuse marked "D". Local codes take
precedence over recommendations.

8.1 Grounding instructions

1. All Grounded, Cord-connected Tools:
In the event of a malfunction or breakdown,
grounding provides a path of least resistance for
electric current to reduce the risk of electric shock.
This tool is equipped with an electric cord having
an
equipment-grounding
grounding plug. The plug must be plugged into a
matching outlet that is properly installed and
grounded in accordance with all local codes and
ordinances.
Do not modify the plug provided - if it will not fit the
outlet, have the proper outlet installed by a
qualified electrician.
Improper connection of the equipment-grounding
conductor can result in a risk of electric shock. The
conductor with insulation having an outer surface
that is green with or without yellow stripes is the
equipment-grounding
replacement of the electric cord or plug is
necessary,
do
grounding conductor to a live terminal.
electrician
or
grounding instructions are not completely
understood, or if in doubt as to whether the
tool is properly grounded. Failure to comply
may cause serious or fatal injury.

8.3 Overload reset

It is recommended that the PM1000 Table Saw
be connected to a dedicated 30 amp circuit with
circuit breaker or time delay fuse. Local codes
take precedence over recommendations.
The on/off switch is thermally protected. If the
saw motor is overloaded, or a momentary
interruption of electrical current is sensed, the
saw will shut off.
Allow a few minutes for saw to cool down, then
reset by pushing the off button.
8.4 Operating Controls
Start/Stop
Power Indicator Light – The start switch has a
power indicator lamp which is on whenever there
is power connected to the saw, not just when the
saw is running. Do not assume that no light means
there is no power to the machine. If the bulb is bad,
there will no indication. Always check before use.
14
conductor
conductor.
If
repair
not
connect
the
equipment-
Check
with
a
service
personnel
and
a
or
qualified
if
the

Hide quick links: