7.4.3 Control Check

A control check should be performed during the periodic inspection
1. Remove the propellers
2. Power on transmitter
3. Install battery and connect power
4. Arm the motors
5. Slowly increase the throttle until the motors begin spinning
6. Test each control input and check that the motors respond as shown in the table below
Control Input
Elevator forward
Elevator backward
Aileron right
Aileron left
Rudder right
Rudder left
7. Disarm the motors
8. Disconnect battery
9. Power off transmitter
Pg. 26
WARNING: Remove propellers before arming
Left Wing
Motor
=
=
faster
slower
faster
slower
Top Pylon
Bottom Pylon
Motor
Motor
faster
slower
slower
faster
=
=
=
=
slower
slower
faster
faster
Right Wing
Motor
=
=
slower
faster
faster
slower