Configuration Menu; Select Temporary Hold Time - Emerson White-Rodgers P210 Install Manual

Table of Contents

Advertisement

6.3 Configuration menu

The configuration menu allows you to set certain thermostat operating characteristics to your system or personal
requirements.
Press RUN to make sure the thermostat is in the run program mode, then press PRGM and RUN at the same time
to enter the configuration menu. The display will show the first item in the configuration menu.
The configuration menu table summarizes the configuration options. An explanation of each option follows.
Press HOLD to change to the next menu item or press TIME to go backwards to the previous item in the menu. To
exit the menu and return to the program operation, press RUN. If no keys are pressed within fifteen minutes, the
thermostat will revert to normal operation.
1. Select Temporary Hold Time – The thermostat can hold any temperature you set it to for the amount of time
you select on this option. Your choices are 0:00 to 8:00 hours in 15 minute increments. 0:00 disables the func-
tion
Example:
1. You have selected 3:00 hours for the Temporary Hold time period.
2. With the thermostat set to Heat or Cool, press HOLD for approximately five seconds until HOLD time (3:00
indicating 3 hours) appears as a setting reminder.
20