Installer Configuration Menu - Emerson 1F97-1277 User Manual

Big blue touchscreen thermostat with automatic heat/cool changeover option
Table of Contents

Advertisement

To enter the menu: Press the Menu touch key . Press and hold for 5 seconds the Installer Config touch key . This displays
menu item #1 in the table below . Press
or
to change a menu item .
Installer Note: To default the programming, clock and Configuration Menu to the Factory Default Settings, press the
and SYSTEM keys simultaneously . The thermostat display will go blank for a few seconds, and then all segments will display
momentarily . For heat pump systems, Configuration Menu item 1 must be set to match the heat pump system.
If first item does not show SS1 or HP1, you have an earlier thermostat model and need Instruction Sheet 37-6814D.
Menu
Non-
Reference
Program-
Program-
Number
mable
mable
1
1
1
2
2
2
3
3
3
4
4
NA
5
5
4
6
6
NA
7
7
5
8
8
6
9
9
7
10
10
8
11
11
9
12
12
10
13
13
11
14
14
12
15
15
13
16
16
14
17
17
15
18
18
16
19
19
17
20
20
18
21
21
19
22
22
20
23
23
21
24
24
22
25
25
23
26
26
24
to advance to the next menu item or
CONFIGURATION MENU
Displayed
Press
Press
(Factory
select from listed
Button
Default)
SS1
HP1, SS1
(ELE)
Days, (7) P
5+1+1 or 0
PS (4)
Cool-Off-
Cool-Off-Heat,
Heat-Auto
Off-Heat, Cool-Off
Cool-Off-Heat-
Cool-Off-Heat-Emer,
Emer-Auto
Off-Heat-Emer,
E (On)
Cr, Heat (FA)
Cr, Cool (FA)
Cr/AU, Emer (FA)
CL (OFF)
dL (On)
dL (LO)
0
4, LO to 4, HI
°F
b (On)
dS (On)
AS, Heat (On)
AS, Cool (On)
CS, (OFF)
1-2-3-4-5-6
Cool Savings
HL, Heat (99)
LL, Cool (45)
L (total), P (partial),
OFF,
Temperature Limit
Keypad Lockout
(limited temperature
000
FS, Heat (On)
Remote (OFF)
In, Remote
Outdoor Remote
LS (On)
dF (5)
Cd (60)
Change Filter
(OFF)
200 Hours
(in increments
of 25 hours)
INSTALLER/CONFIGURATION MENU
to return to a previous menu item . Press
or
to
options
Comments
Selects Single Stage or Heat Pump
(1 compressor)
GAS
GAS setting: furnace controls blower
ELE setting: thermostat controls blower
Programs per week . (0 = non-programmable)
2
Program periods per day
4 = Morning, Day, Evening, Night
2 = Day, Night
System switch configuration in single stage
System switch configuration, heat pump mode
Cool-Off
OFF
Selects Energy Management Recovery, E (with programming option on)
SL
Selects Adjustable Anticipation, cycle rate, Heat
SL
Selects Adjustable Anticipation, cycle rate, Cool
SL
Selects Adjustable Anticipation, cycle rate auxiliary, (This item is
only to appear if HP1 is selected above)
On
Selects Compressor Lockout
OFF
Selects Continuous Display backlight & intensity
HI
Selects Backlight Intensity
Selects Adjustable Ambient Temperature Display [range -4 (LO)
to +4 (HI)]
°C
Selects °F/°C Display (temperature units in Fahrenheit or Celsius) .
OFF
Selects audible Beeper On/Off
OFF
Selects Daylight Saving Time calculation
OFF
Selects Automatic Schedule for comfort temperature Programming,
heat mode
OFF
Selects Automatic Schedule for comfort temperature Programming,
cool mode
Selects Cool Saving Feature & amount
62-98
TEMPERATURE LIMIT, HEAT (max . heat set point)
46-82
TEMPERATURE LIMIT, COOL (min . cool set point)
Selects Keypad Lockout
range)
001-999
Selects Keypad Lockout Combination (active only if keypad Lockout
is selected) .
OFF
Fast second stage of heat (not available if SS1 is selected above)
On
Remote temperature sensor, enable/disable
Remote temperature sensor (Indoor/Outdoor)
OFF
Local temp . Sensor enable/disable (only when Indoor Remote is
selected On) .
5-50
Selects Dual Fuel Feature & set point (in Fahrenheit)
(applicable only when HP1 is selected)
0-99
Selects Compressor delay in seconds (only when dF is selected >5)
On
Selects Change filter feature
25-1975
Change filter, duration hours
,
5

Advertisement

Table of Contents
loading

Table of Contents