INSTALLER/CONFIGURATION MENU

To enter the Configuration Menu, SYSTEM must be set to HEAT, COOL, Em or AUTO. Press the Menu button for at least 5
seconds. The display will show item #1 in the table below. Press Menu button to advance to the next menu item. Press
to change an item option. Shaded items are not available on 1F86.
Menu
Screen
SS
HP
(Factory Default)
Number
01
02
03
(Cool O) On
04
05
Cool Savings CS
06
07
08
09
10
CR Heat Pump
11
12
13
14
15
16
17
18
 (OFF) Change Filter
19
(200 h) Change
1 & 2)Keypad Lockout – This menu selection will display
"Lk" and "OFF" (default, keypad not locked out). The
and
are used to toggle the selection between
OFF and "L" (keypad locked out). When the keypad
lockout selection is enabled "L", and the MENU button
is pressed again, the display will indicate the number
"0" (default, still disabled) in the time digits. The
and
are used to set the combination number from 0
to 999. If a combination of 0 is selected and the MENU
button is pressed, the menu will be exited and keypad
will not be locked. If 1 to 999 is selected and the MENU
button is pressed, the combination is stored into memory
and the menu is exited. The "Lk" will display designating
keypad locked with a valid combination. The SYSTEM
button will operate for 10 seconds after the menu mode
is exited to allow the user to change the mode from
"OFF" to the desired SYSTEM mode.
While the keypad is locked out, a press of MENU will en-
ter the configuration menu. The first menu item displayed
is the combination code "0". The
used to set the combination unlock number from 0 to
4
INSTALLER/CONFIGURATION MENU
Displayed
Press
select from listed options
(OFF) Lk
(000) Lk
001 to 999
Heat b On
(2) P
P 3, P 0
(OFF)
Cool Savings CS On
(3) CS
6, 5, 4, 3, 2, 1
(On) E
E OFF
(ME)
SL, FA
CR Heat
(FA)
CR Cool
(FA)
(OFF) CL
Auto-Heat
Heat-Cool-Off, Heat-Off
Cool-Off
with Fan icon,
Heat-Off without Fan icon,
Cool-Off, Auto-Off
(On) dL
0 HI
1 HI, 2 HI, 3 HI, 4 HI,
1 LO, 2 LO, 3 LO, 4 LO
°
F
L (90) Heat
L 62 to L 89
L (45) Cool
L 46 to L 82
Change Filter On
25 h to 1975 h in
Filter
25-hour increment
or
keys are
or
to
L
Selects Keypad lockout combination number
Reversing Valve Output (SS/HP switch must be in
Selects Cool Savings value 1 (low) to 6 (high)
Selects Energy Management Recovery (EMR)
Adjustable Anticipation (Heat) (only when SS/HP
SL
Adjustable Anticipation (Cool) (only when SS/HP
SL
(only when SS/HP switch is at the HP position)
CL On
System Mode Configuration with Automatic
OFF
Adjustable Ambient Temperature Display
°
Selects Fahrenheit/Celsius Temperature Display
C
When on, selects time in 25 hour increments
999. If the unlock number matches exactly with the com-
bination lock number stored in memory when the MENU
button is pressed, the keypad is unlocked and the "Loc"
is removed. If the unlock number does not match when
the MENU button is pressed, the combination returns to
"0" for another attempt to set the unlock code. To exit the
menu without unlocking the keypad, press RUN SCHED.
To reset the combination code and unlock the keypad if
the code is forgotten, see troubleshooting section.
3) Select Reversing Valve Output (SS/HP switch must be set
at HP, omitted if SS/HP switch is SS Position) – The O/B
option is factory set at "O" position. This will accommodate
the majority of heat pump applications, which require the
changeover relay to be energized in COOL. If the thermo-
stat you are replacing or the heat pump being installed
with this thermostat requires a "B" terminal, to energize the
changeover relay in HEAT, the O/B option should be set at
"B" position.
Comments
Selects Keypad Lockout.
(Not available on earlier models)
the Heat Pump HP position)
Selectable Programs Per Week
(For programmable thermostat only)
Select Cool Savings On of OFF
On or OFF
(For programmable thermostat only)
switch is at the SS position)
switch is at the SS position)
Adjustable Anticipation (Heat Pump)
Compressor Lockout Time
Changeover
Selects Display Light On or OFF
Selects Limited HEAT Range
Selects Limited COOL Range
Selects Filter Change-out Indicator
25-hour increment
or