Shipping Inspection; Electrostatic Discharge (Esd) Precautions - Goodman GMSS96 Installation Instructions Manual

Table of Contents

Advertisement

CO can cause serious illness including permanent brain
damage or death.
S
I
HIPPING
NSPECTION
All units are securely packed in shipping containers tested accord-
ing to International Safe Transit Association specifications. The
carton must be checked upon arrival for external damage. If dam-
age is found, a request for inspection by carrier's agent must be
made in writing immediately.
The furnace must be carefully inspected on arrival for damage and
bolts or screws which may have come loose in transit. In the event
of damage the consignee should:
1. Make a notation on delivery receipt of any visible damage to
shipment or container.
2. Notify carrier promptly and request an inspection.
3. With concealed damage, carrier must be notified as soon as
possible - preferably within five days.
4. File the claim with the following support documents within a nine month statute of limitations.
Original or certified copy of the Bill of Lading, or indemnity bond.
Original paid freight bill or indemnity in lieu thereof.
Original or certified copy of the invoice, showing trade and other discounts or reductions.
Copy of the inspection report issued by carrier's representative at the time damage is reported to carrier.
The carrier is responsible for making prompt inspection of damage and for a thorough investigation of each claim. The distributor or
manufacturer will not accept claims from dealers for transportation damage.
E
D
LECTROSTATIC
ISCHARGE
NOTE: Discharge your body's static electricity before touching unit. An electrostatic discharge can adversely affect electrical
components.
Use the following precautions during furnace installation and servicing to protect the integrated control module from damage. By
putting the furnace, the control, and the person at the same electrostatic potential, these steps will help avoid exposing the
integrated control module to electrostatic discharge. This procedure is applicable to both installed and non-installed (ungrounded)
furnaces.
1. Disconnect all power to the furnace. Do not touch the integrated control module or any wire connected to the control prior to
discharging your body's electrostatic charge to ground.
2. Firmly touch a clean, unpainted, metal surface of the furnaces near the control. Any tools held in a person's hand during
grounding will be discharged.
Advertencia especial para la instalación de calentadores ó manejadoras
de aire en áreas cerradas como estacionamientos ó cuartos de servicio.
Las emisiones de monóxido de carbono pueden circular a través
del aparato cuando se opera en cualquier modo.
El monóxido de carbono puede causar enfermedades severas
como daño cerebral permanente ó muerte.
B10259-216
(ESD) P
RECAUTIONS
RISQUE D'EMPOISONNEMENT AU MONOXYDE DE CARBONE
Cette ventilation est nécessaire pour éviter le danger d'intoxication
au CO pouvant survenir si un appareil produisant du monoxyde
de carbone continue de fonctionner au sein de la zone confinée.
B10259-216
Le monoxyde de
des
S
HOULD OVERHEATING OCCUR OR THE GAS SUPPLY FAIL TO SHUT OFF
TURN OFF THE MANUAL GAS SHUTOFF VALVE EXTERNAL TO THE
FURNACE BEFORE TURNING OFF THE ELECTRICAL SUPPLY
P
OSSIBLE PROPERTY DAMAGE
,
,
,
FIRE
EXPLOSION
SMOKE
OR CARBON MONOXIDE MAY RESULT FROM IMPROPER INSTALLATION
,
REPAIR OPERATION
OR MAINTENANCE OF THIS PRODUCT
4
carbone peut causer des maladies graves telles que
dommages permanents au cerveau et meme la mort.
WARNING
.
WARNING
,
PERSONAL INJURY OR DEATH DUE TO
,
,
SOOT
CONDENSATION
ELECTRICAL SHOCK
.
B10259-216
,
,