The bearings in the induced draft blower and circulator blower motors are permanently lubricated by the manufacturer. No further
lubrication is required. Check motor windings for accumulation of dust which may cause overheating. Clean as necessary.
C
T
D
ONDENSATE
RAP AND
Annually inspect the drain tubes, drain trap, and field-supplied drain line for proper condensate drainage. Check drain system for
hose connection tightness, blockage, and leaks. Clean or repair as necessary.
F
S
(Q
LAME
ENSOR
UALIFIED
Under some conditions, the fuel or air supply can create a nearly invisible coating on the flame sensor. This coating acts as an
insulator causing a drop in the flame sense signal. If the flame sense signal drops too low the furnace will not sense flame and will lock
out. The flame sensor should be carefully cleaned by a qualified servicer using emery cloth or steel wool. Following cleaning, the
flame sense signal should be as indicated in the Specifications Sheet.
F
P
(Q
LUE
ASSAGES
UALIFIED
The heat exchanger flue passageways should be inspected at the beginning of each heating season.
B
L
I
EFORE
EAVING AN
NSTALLATION
Cycle the furnace with the thermostat at least three times. Verify cooling and fan only operation.
Review the Owner's Manual with the homeowner and discuss proper furnace operation and maintenance.
Leave literature packet near furnace.
R
R
EPAIR AND
EPLACEMENT
When ordering any of the listed functional parts, be sure to provide the furnace model, manufacturing, and serial numbers
with the order.
Although only functional parts are shown in the parts list, all sheet metal parts, doors, etc. may be ordered by description.
Parts are available from your distributor.
Functional Parts List-
Gas Valve
Natural Gas Orifice
Igniter
Rollout Limit Switch
Coil Front Cover
Induced Draft Blower
B
LOWERS
S
(Q
S
RAIN
YSTEM
UALIFIED
S
O
)
ERVICER
NLY
S
O
)
ERVICER
NLY
P
ARTS
Blower Motor
Blower Mounting Bracket
Blower Housing
Door Switch
Integrated Control Module
O
)
ERVICER
NLY
Gas Manifold
Propane Gas Orifice

Flame Sensor

Primary Limit Switch
Transformer
Heat Exchanger with Recuperator Coil
41
Blower Wheel
Blower Cutoff
Pressure Switch
Auxiliary Limit Switch
Door Switch

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents