IBM eServer 135 xSeries User Reference Manual page 99

Hide thumbs Also See for eServer 135 xSeries:
Table of Contents

Advertisement

Table 14. Diagnostic error messages
Code
Function
405
Ethernet
415
Analog/digital
modem
Result
Failed
In PCI slot n
(where n is the PCI slot number in which the failing
Ethernet adapter is installed)
On system board
Not
No modem was detected
applicable
PCI modem detected but not enabled
Failed
Modem reset failed
No dialtone detected
Text message
Action
Replace the Ethernet
adapter in slot n. If the
problem persists, call for
service.
Call for service.
1. Verify that the
modem is properly
attached to the
server.
2. If the problem
remains, replace the
modem.
If the problem persists,
call for service.
1. Change the
configuration to
enable the modem.
2. If the problem
remains, replace the
modem.
If the problem persists,
call for service.
Replace the modem.
If the problem persists,
call for service.
1. Make sure that the
phone line attached
to the modem has a
dial tone. (Connect
a phone to the line
and listen, if
necessary.) If there
is no tone, have the
phone line serviced.
2. If the problem
remains, replace the
modem.
If the problem persists,
call for service.
Chapter 6. Solving Problems