Diagnostic Error Message Tables - IBM eServer 135 xSeries User Reference Manual

Hide thumbs Also See for eServer 135 xSeries:
Table of Contents

Advertisement

Diagnostic error message tables

Table 14. Diagnostic error messages
Code
Function
001
Core system
005
Video port
011
Serial port
014
Parallel port
015
USB interface
020
PCI interface
030
SCSI interface
075
Power supply
82
IBM xSeries 135: User's Reference
The following tables provide descriptions of the error messages that might appear
when you run the diagnostic programs.
Important
If diagnostic error messages appear that are not listed in the following tables,
make sure that your server has the latest levels of BIOS and diagnostics
microcode installed.
Result
Failed
Processor board, ECC Test
System board
Processor and system boards
Integrated serial port
Integrated parallel port
Aborted
Can NOT test USB interface while it is in use.
Note:
If you have a USB keyboard or mouse
attached, you cannot run the diagnostic
program for the USB interface.
Failed
System board
Failed
System board
Failed
SCSI adapter in slot n failed register/counter/ power
test
(where n is the slot number of the failing adapter)
SCSI controller on system board failed
register/counter/power test
Failed
Voltage sensed by the system is out of range
Text message
Action
Call for service.
1. Turn off the server.
2. Replace the USB
keyboard and
mouse with a
standard keyboard
and mouse.
3. Turn on the server.
4. Run the diagnostic
test again.
Call for service.
Call for service.
Refer to the information
provided with the
adapter for instructions.
If the problem persists,
call for service.
Call for service.
Call for service.

Advertisement

Table of Contents
loading