Table 14. Diagnostic error messages
Code
Function
089
Microprocessor
Result
Failed
Invalid microprocessor in slot xyz or BIOS setup
problem
(where xyz identifies the microprocessor that is
causing the error message)
Processor in socket id xyz is installed but not
functioning
(where xyz identifies the microprocessor that is
causing the error message)
Microprocessor in socket id xyz
(where xyz identifies the microprocessor that is
causing the error message)
Processor in socket id xyz is defective
(where xyz identifies the microprocessor that is
causing the error message)
Test setup error: Application microprocessor not
installed or BIOS setup problem
Text message
Action
1. Check the system
error log for the
related error
messages.
2. If your server does
not have the latest
level BIOS
installed, update
the BIOS.
3. If the problem
remains, replace the
xyz microprocessor
and run the test
again.
If the problem persists,
call for service.
1. Reseat the
microprocessor.
2. If the problem
remains, replace the
microprocessor.
If the problem persists,
call for service.
Replace the
microprocessor.
If the problem persists,
call for service.
1. Verify that the
Application
microprocessor is
installed and seated
correctly.
2. If your server does
not have the latest
level BIOS
installed, update
the BIOS.
3. If the problem
remains, replace the
application
microprocessor and
run the test again.
If the problem persists,
call for service.
Chapter 6. Solving Problems