Technibel CAFP 124 R Technical Data & Service Manual page 27

Package air conditioner dc inverter r410a
Hide thumbs Also See for CAFP 124 R:
Table of Contents

Advertisement

1-1. Unit Specifications
Concealed-Duct Type DSAFP255R x 2 / GRFP255R
MODEL No.
POWER SOURCE
PERFORMANCE
Capacity [minimum~maximum]
Air circulation (Hi/Me/Lo)
Moisture removal (High)
External static pressure (High)
ELECTRICAL RATINGS
Voltage rating
Available voltage range
Running amperes*
Max–Running amperes**
Power input
C.O.P
Max. Starting amperes
FEATURES
Controls/Thermostat control
Timer
Fan speeds Indoor/Outdoor
Airflow direction (Indoor)
Air filter
Remote controller (Option)
Refrigerant control
Drain pump (Drain connection)
Compressor
Operation sound
Color (Approximate value)
REFRIGERANT TUBING
Limit of tubing length
Limit of tubing length at shipment
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipment
DIMENSIONS & WEIGHT
Unit dimensions
Package dimensions
Net weight
Shipping weight
Shipping volume
Cooling:
Rating conditions (*):
Full load conditions (**):
Heating:
Rating conditions (*):
Full load conditions (**):
Indoor Unit
Outdoor Unit
Pa(mmAq)
Indoor - Hi/Me/Lo
Outdoor - Hi
Indoor
Outdoor
Narrow tube
Wide tube
Height
Width
Depth
Height
Width
Depth
m
Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
220 - 230 - 240 V/1 phase/50/60 Hz
Cooling
kW
12.5 [2.7~14.0]
BTU/h
42,500 [9,200~48,000]
m3/h
2,160/1,800/1,560 (1,080/900/780x2)
Liters/h
7.0 (3.5x2)
50 (5.1) : at shipment,92 (9.4) : using the booster cable
V
220
230
V
198 - 264
A
22.2
21.3
A
kW
4.39
4.42
W/W
2.85
2.83
A
Microprocessor/I.C.thermostat
3 and Automatic control/Variable
Wired : REM HW
Max.head 50 cm above drain connection (25A , OD32mm)
dB - A
34/30/27, (38/34/30 : using the booster cable)
dB - A
m (ft.)
m (ft.)
m (ft.)
Outdoor unit is higher than indoor unit : 30 (98)
Outdoor unit is lower than indoor unit : 15 (49)
mm (in.)
mm (in.)
kg
Indoor unit
mm (in.)
310 (12-7/32)
mm (in.)
1,000 (39-12/32)
mm (in.)
630 (24-26/32)
mm (in.)
358 (14-3/32)
mm (in.)
1,191 (46-28/32)
mm (in.)
783 (30-26/32)
kg (lb.)
32 (71)
37 (82)
kg (lb.)
0.334 (11.8)
3
(cu. Ft)
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
1 - 25
DSAFP255R x 2
GRFP255R
Heating
14.0 [2.7~16.0]
48,000 [9,200~54,500]
240
220
230
198 - 264
20.6
21.9
21.0
4.45
4.33
4.35
2.81
3.23
3.22
ON/OFF 72-hours
Field supply
Wireless : REM HL
Rotary(SANYO)
52/53
Munsell 1Y 8.5/0.5
50 (164)
5~30 (16~98)
9.52 (3/8)
15.88 (5/8)
R410A - 3.6
Outdoor unit
1230 (48- 7/16)
940 (37)
340 (13-3 /8)
1330 (52-3 /8)
1015 (39-31/32)
409 (16-3/32)
100 (220)
109 (240)
0.552 (19.5)
1
240
20.2
4.38
3.20