Further Support
To find out more about how Solar iBoost+ works visit
Consult your qualified installer / electrician for any user queries.
Technical support for qualified installers and electricians +44 (0) 1536 447866
Important Information about Legionella
Legionella bacteria are common and can be found naturally in environmental water
sources such as rivers, lakes and reservoirs, usually in low numbers. As legionella
bacteria are commonly encountered they may eventually colonise manufactured water
systems and if conditions are favourable the number of bacteria may grow. Contamination
risks are however low due to the low availability of nutrients and the regular chlorination of
the water supply.
As with any hot water storage system it is important to avoid water stagnation and ensure
the water is regularly heated to a minimum temperature of 55-60°C to reduce potential
risks.
It is therefore recommended that the hot water tank be heated to 55-60°C at least once
per week either using Boost facility or through other heating controls.
Limited Warranty
The SIB Energy Company Limited Warranty provides free replacement cover for all
defects in parts and workmanship for 24 months from the date of purchase. SIB Energy
Ltd obligation in this respect is limited to replacing parts which have been promptly
reported to the seller and are in the seller's opinion defective and are so found by SIB
Energy Ltd upon inspection. A valid proof of purchase is required if making a warranty
claim.
Defective parts must be returned by prepaid post and accompanied by a Returns
Authorisation available in advance from Marlec Engineering Company Limited, Rutland
House, Trevithick Road, Corby, Northamptonshire, NN17 5XY, England, or to an
authorised agent.
This Warranty is void in the event of improper installation, unauthorised service, use of
unauthorised components, owner neglect, misuse or natural disasters including lightning
strike. This warranty does not extend to ancillary equipment not supplied by the
manufacturer. No responsibility is assumed for incidental damage. No responsibility is
assumed for consequential damage.
Disclaimer
SIB Energy Limited has a policy of continuous improvement in product quality and design.
The company, therefore reserves the right to change the specification of its models at any
time. All items in this guide are for illustration purposes only and may not apply to your
particular situation.
Disposal of Old Electrical Appliances
For electrical products sold within the European Community. At the end of
this products useful life, it should not be disposed of with household waste.
Please recycle where facilities exist. Check with your local authority or retailer
for recycling advice in your local area.
SIB Energy Limited
www.solariboost.co.uk
⁞
Peterborough
⁞
19
PE3 6SR
Need help?
Do you have a question about the Solar iBoost+ and is the answer not in the manual?
Questions and answers
Since my Solar I-boost was installed in 2014, when I had no battery storage, I have had retrofit Pylon 2 x 3.5kWh batteries and then a new generation system installed with 3 x Fox EP5 5.18kWh batteries - ie a total BESS od 22.54 kWh x 90% = 20+ kWh of usable storage - and so my I-boost is only heating the water when I have SOC 100% = 22.54 kWh stored. But can I not leave my gas HW heating off and simply press the manual boost and use any available battery storage ??