6. Specifications

CAPACITY*
INPUT
Low Line Transfer
Voltage
Low Line Comeback
Range
High Line Transfer
High Line Comeback
Frequency Range
Phase
Power Factor
OUTPUT
Output voltage
AC Voltage Regulation
Frequency Range
(Synchronized Range)
Frequency Range (Batt. Mode)
Overload
Current Crest Ratio
Harmonic Distortion
Transfer
AC Mode to Batt. Mode
Time
Inverter to Bypass
Waveform (Batt. Mode)
EFFICIENCY
AC Mode
Battery Mode
BATTERY
Battery Type
Numbers
Standard
Recharge Time
Model
Charging Current
Charging Voltage
Battery Type &
Numbers
Long-run
Model
Charging Current
Charging Voltage
PHYSICAL
Tower
Dimension, D X W X H
Case
Net Weight (kgs)
Dimension, D X W X H
Rack
Case
Net Weight (kgs)
ENVIRONMENT
Operation Humidity
Noise Level
MANAGEMENT
Smart RS-232 or USB
Optional SNMP
* Derate capacity to 60% of capacity in Frequency converter mode and to 80% when the output voltage is adjusted to
208VAC.
1000 VA / 800 W
1500 VA / 1200 W 2000 VA / 1600 W
160 VAC / 140 VAC / 120 VAC / 110 VAC ± 5 % or 80 VAC / 70 VAC / 60 VAC / 50
( based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0)
≧ 0.99 @ 220-230 VAC (input voltage)
208/220/230/240VAC or 110/115/120/127 VAC
110%-130%: UPS shuts down in 30 seconds at battery mode or transfers to bypass
>130%: UPS shuts down immediately at battery mode or transfer to bypass mode
≦ 3 % THD (Linear Load)
≦ 6 % THD (Non-linear Load)
~ 85%
12 V / 7 AH
3
4 hours recover to 90% capacity (Typical)
41.0 VDC ± 1%
Depending on the capacity of external batteries
41.0 VDC ± 1%
397 X 145 X 220 (mm)
13
7
420x438x88[2U] (mm)
16
10
20-90 % RH @ 0- 40°C (non-condensing)
Supports Windows® 2000/2003/XP/Vista/2008/7, Linux, Unix and MAC
Power management from SNMP manager and web browser
18
VAC ± 5 %
175 VAC ± 5 % or 85 VAC ± 5 %
300 VAC ± 5 % or 150 VAC ± 5 %
290 VAC ± 5 % or 145 VAC ± 5 %
40Hz ~ 70 Hz
Single phase with ground
± 3% (Batt. Mode)
47 ~ 53 Hz or 57 ~ 63 Hz
50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz
100%~110%: audible warning
mode when the utility is normal.
when the utility is normal.
3:1
≦ 7 % THD (Non-linear Load)
Zero
4 ms (Typical)
Pure Sinewave
~ 83%
12 V / 9 AH
12 V / 7 AH
3
1.0 A(max.)
4.0 A or 8.0 A(max.)
14
7
26
17
10
29
Less than 45dBA @ 1 Meter
3000 VA / 2400 W
≦ 4 % THD (Linear Load)
~ 88%
12 V / 9 AH
6
6
82.1 VDC ± 1%
82.1 VDC ± 1%
421 X 190 X 318 (mm)
13
28
580x438x133[3U] (mm)
17
31
13
17