Installation & Operation
1.
Inspection
The following items are inside the box:
●UPS unit & User manual
Remove the UPS from its package and inspect it for damage that
may have occurred during shipping. If any damage is discovered,
re-pack the unit and return it to the place of purchase.
2.
Connect to Utility Power
Connect AC power cord to utility power. Then, the UPS will start
to charge inside battery. For best result, charge the battery for 6
hours prior to initial use.
3.
Connect Modem/Phone Line/Network(only for
the model with RJ 11/45 port)
This UPS protects a single line (1 in/1 out) phone, modem, or fax
machine from surges when connected through the UPS. Plug in
conning Internet line into the "IN" socket. Use one more Internet
line cable in the "OUT" socket and plug one other end to the
modem input socket.
4.
Plug in Equipment
Plug your equipment to Battery Backup Outlets on the rear panel
of the UPS.
NOTE: Make sure that the UPS is powered on to protect all
important devices from data loss during power failure.
CAUTION: NEVER connect a laser printer or scanner to the
battery backup outlets of UPS. The equipment may draw
significantly power to overload the UPS.
5.
Connect Com. Port and Install Software(only
for the model with USB com. port)
Connect one end of the USB cable to PC and the other to the
USB port at the rear of the UPS.
Product Overview
1: Power switch with status indicator
2: Modem/Phone line/Network surge protection
3: AC input
4: Circuit breaker
5: Battery backup outlets (Schuko*3~4, Universal*3, UK*3, NEMA*4~5)
6: Options*
USB com. port /
*This option is not available for the selection of 4 x schuko
FSP Manual Guide
Operation:
1.
LED will light up.
2.
LED will go off.
3.
cold start the UPS unit to power the loads.
LED Indicator:
LED
●LED on ○ LED Off ★ LED flashing
The unit can be mounted to a wall surface.
1.
2.
3.
Placement:
and has adequate air flow. Place the UPS away from other units at least
20 cm to avoid interference. For best performance, keep the indoor
temperature between 0° C and 40° C.
Storage:
the UPS to avoid battery drain. Unplug the UPS from the wall outlet.
Then turn off the UPS for storage.
upright in environments where the ambient temperature is -20° C to 50°
C with its battery fully charged.
USB charger
Operation & Function
Turn On the UPS
To turn on the UPS unit, press the power switch lightly. Then, the
Turn Off the UPS
To turn off the UPS unit, press the power switch again. Then, the
Cold Start Function
When the UPS is off and there is no power utility, it's stil l possible to
Alarm
Off
Sounding every 10 seconds
Sounding every second
Off
Continuously sounding
MOUNTING UPS
Use a ruler to draw a straight line in 222 mm
horizontally on the wall. (see chart 1)
Use a sharp nail to puncture the center of the two
ends to mark the wall.
Mount the unit by positioning the key-hole slots
over the mounting nails. (see chart 2)
Placement & Storage
Install the UPS in a protected area that is free of excessive dust
All connected equipment should be turned off, then disconnect from
Line-interactive UPS
ECO 400VA~800VA
UPS Status
The mains is normal and UPS
is operated normally.
Power failure occurs and UPS
is on battery mode.
Low battery
UPS is off.
UPS fault
Chart 1
Chart 2
Store the UPS unit covered and

Advertisement

loading

Summary of Contents for FSP Technology ECO 600

  • Page 1 Line-interactive UPS FSP Manual Guide ECO 400VA~800VA Installation & Operation Operation & Function Inspection Operation: Turn On the UPS The following items are inside the box: ●UPS unit & User manual To turn on the UPS unit, press the power switch lightly. Then, the •...
  • Page 2: Troubleshooting

    Line-interactive UPS FSP Manual Guide ECO 400VA~800VA Safety caution • To reduce the risk of overheating the UPS, do not cover the UPS' cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space This manual contains important instructions that heater or furnaces.
  • Page 3 Pohotovostní UPS FSP Manual Guide ECO 400VA~800VA Provozní zobrazení Instalace a provoz Provozní: Zapněte UPS Kontrola Uvnitř balení jsou následující položky: Jednotku UPS zapnete lehkým stisknutím vypínače. Poté se ●Jednotka UPS & Návod k použití rozsví tí LED. Vypněte UPS •...
  • Page 4 Pohotovostní UPS FSP Manual Guide ECO 400VA~800VA Bezpečnostní opatrnost • Upozornění – nebezpečí úrazu elektrickým proudem. I po odpojení této jednotky od hlavního napájení může být nebezpečné napětí stále přístupné z akumulátoru. Z tohoto Tato příručka obsahuje důležité pokyny, které je třeba důvodu je nutné...
  • Page 5 Line-interaktive USV FSP Manual Guide ECO 400VA~800VA Installation und Betrieb Bedienung & Funktion Inspektion Schalten Sie die USV ein Die folgenden Artikel sind im Lieferumfang enthalten: ●USV-Gerät & Bedienungsanleitung Drücken Sie den Netzschalter leicht, um die USV-Einheit • Nehmen Sie die USV aus ihrer Verpackung und prüfen Sie sie auf einzuschalten.
  • Page 6: Fehlerbehebung

    Line-interaktive USV FSP Manual Guide ECO 400VA~800VA • Ersetzen Sie Akkus immer mit der gleichen Anzahl und dem Sicherheitshinweis gleichen Typ an versiegeltem Bleiakku. • Ö ffnen und beschädigen Sie Akkus nicht. Auslaufendes Elektrolyt schadet Haut und Augen. Es könnte giftig sein. Dieses Handbuch enthält wichtige Anweisungen, die •...
  • Page 7 Onduleur de secours FSP Manuel d’utilisation ECO 400VA~800VA Installation et fonctionnement Opération et Fonction Inspection Opération: Allumez l'onduleur Les éléments suivants sont à l'intérieur de l'emballage : ●Onduleur & Manuel de l’utilisateur Appuyez légèrement sur l’interrupteur d’alimentation. Ensuite, la • Retirez l'onduleur de son emballage et vérifiez la présence de LED s'allume.
  • Page 8: Dépannage

    Onduleur de secours FSP Manual d’utilisation ECO 400VA~800VA nombre et le même type de batteries plomb-acide scellées. Avertissement de sécurité • N'ouvrez pas et n'abî mez pas la ou les batteries. L'électrolyte libéré est nocif pour la peau et les yeux. Cela peut être toxique. •...

This manual is also suitable for:

Eco 400Eco 800