Checking starter
Connect voltmeter between positive and nega-
tive pole of battery.
Operate starter for 2...3 seconds.
Read off value.
L
Note:
If the read-off value is below 8 Volt, this indicates the
battery does not have its full capacity.
Note down value if measured value is above 8 Volt.
Connect voltmeter between positive and nega-
tive lead at starter.
Operate starter for 2...3 seconds.
Read off measured value and compare with the
value noted down.
L
Note:
The starter is defective if the difference between the
two values is greater than 0.5 Volt.