Make Electrical Connections For In-Line Blower Motor System - KitchenAid KXW9748YSS Installation Instructions And Use & Care Manual

Designer wall-mount canopy range hood
Table of Contents

Advertisement

Available languages

Available languages

Install In-line Blower System
NOTE: The blower motor housing can be mounted using 4 holes
from either the outlet side or the inlet side of the blower.
Outlet Side:
A
A
A. Mounting holes
Inlet Side:
A
A. Mounting holes
1. Position the in-line blower motor housing in its mounting
location, and mark the 4 mounting hole locations.
2. Drill 4 mounting pilot holes using a
3. Attach the in-line blower motor housing to the mounting
location with four 6 x 80 mm mounting screws and washers.
4. If it is removed, reinstall the blower motor assembly and
secure it with the screws previously removed.
5. If it is removed, reattach the motor electrical plug to the
connector on the blower motor assembly.
Complete Preparation
1. Determine and make all necessary cuts for the vent system.
IMPORTANT: When cutting or drilling into the ceiling or wall,
do not damage electrical wiring or other hidden utilities
2. Determine the location where the
will be routed through the ceiling or wall between the in-line
blower and the range hood.
3. Drill a 1
/
" (3.2 cm) hole at this location.
1
4
A
A
A
/
" (4.8 mm) drill bit.
3
16
/
" (1.3 cm) wiring conduit
1
2
4. Locate the electrical terminal boxes in the in-line blower
housing and range hood. Remove the terminal box covers
and set the covers and screws aside.
B
A
A. Electrical terminal box
B. Electrical knockout
5. Remove the electrical knockout from the in-line blower
housing and range hood to prepare for the installation of
the UL listed or CSA approved
and conduit connector.
6. With the range hood mounted (see the "Install Range
Hood" section), run the
between the in-line blower motor housing and the range
hood. Pull enough
/
" (1.3 cm) wiring conduit to allow for
1
2
easy connection to the terminal boxes in the in-line blower
housing and range hood.
7. Run the six 18 AWG wires through the
conduit and conduit connectors and into the terminal
boxes on the in-line blower housing and range hood.
Leave enough wire length in each terminal box to make
the wiring connections.
8. Install the conduit connectors and conduit to the in-line
blower housing and range hood electrical terminal boxes.
9. Connect the vent system to the range hood and in-line
blower system, and seal all joints with clamps.
Make Electrical Connections for In-Line
Blower Motor System
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
Electrical Connection Inside In-line Blower System:
1. Disconnect power.
/
" (1.3 cm) wiring conduit
1
2
/
" (1.3 cm) wiring conduit
1
2
/
" (1.3 cm) wiring
1
2
11