PRODUCT SPECIFICATIONS
This appliance has been certifi ed for use with either
natural or propane gas. See appropriate data plates.
This appliance is not for use with solid fuels.
The appliance is approved for bedroom or bedsitting
room installations.
The appliance must be installed in accordance with local
codes if any. If none exist use the current installation
code. ANSI Z223.1/NFPA 54 in the USA, CSA B149 in
Canada.
This appliance is mobile home approved.
The appliance must be properly connected to a venting
system.
The appliance is not approved for closet or recessed
installations.

HIGH ELEVATIONS

Input ratings are shown in BTU per hour and are certifi ed
without deration for elevations up to 4,500 feet (1,370
m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current ANSI
Z223.1/NFPA 54 and/or local codes having jurisdiction.
In Canada, please consult provincial and/or local author-
ities having jurisdiction for installations at elevations
above 4,500 feet (1,370 m).

GAS PRESSURES

Inlet Minimum
4.5" w.c.
Inlet Maximum
10.5" w.c.
Manifold Pressure
3.5" w.c.
20306743
Natural
Propane (LP)
11.0" w.c.
13.0" w.c.
10.0" w.c.
KSTDV Series Gas Fireplace
Figure 1 -
KSTDV Controls
GAS SPECIFICATIONS & ORIFICE SIZE
Max. All
Model
Fuel
Burners
KSTDV500
Nat.
KSTDV500
LP
Model
Fuel
KSTDV500
Nat.
KSTDV500
LP
Control Box
Gas Valve
Command
Center
BTU/HR Input
Min. All
Burners
Burners
56,000
37,000
56,000
44,000
Orifi ce Size
Front (2)
Middle
#46
#29
#56
#50
Front
Only
30,000
27,000